Occupancy data at different spatial resolutions: Building energy performance and model calibration

Journal

APPLIED ENERGY
Volume 286, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2021.116492

Keywords

Occupant modeling; Building performance simulation; Building simulation; Bayesian calibration; Uncertainty analysis

Funding

  1. National University of Singapore [R-296-000-190-133]

Ask authors/readers for more resources

This study investigates the impact of different spatial resolutions of occupancy data on building energy use prediction accuracy, finding that deriving occupancy and plug-load schedules from WiFi data can improve the accuracy of building energy models. However, increasing spatial resolution may lead to trade-offs between parameter uncertainty and model bias/inadequacy.
Occupancy is a significant area of interest within the field of building performance simulation. Through Bayesian calibration, the present study investigates the impact of the availability of different spatial resolution of occupancy data on the gap between predicted and measured energy use in buildings. The study also examines the effect of occupancy data on the quality of the constructed prediction intervals (PIs) using the Coverage Width-based Criterion (CWC) metric. CWC evaluates the PIs based on both their coverage (correctness) and width (informativeness). This investigation takes the form of an actual building case study, with nine months of hourly measured building electricity use, WiFi connection counts as a proxy for occupancy, and actual weather data. In general, the building energy model's accuracy improves with the occupancy and plug-loads schedule derived from WiFi data. Specifically, the Coefficient of Variation Root Mean Square Error (CV[RMSE]) reduced from 37% to 24% with an exponential improvement in the PIs quality compared to the results obtained with ASHRAE 90.1 reference schedules. However, the increase in prediction accuracy shrank to 5% CV(RMSE) and a comparable CWC upon calibrating the base loads of the reference schedules. Increasing the spatial resolution from building aggregated to floor aggregated occupancy data worsened the CV(RMSE) and CWC, suggesting trade-offs between parameter uncertainty and model bias/inadequacy. These results contribute to our understanding of the interactions between model complexity, simulation objectives, and data informativeness, facilitating future discussions on the right level of abstraction when modeling occupancy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available