4.7 Article

Robotic Versus Laparoscopic Ventral Hernia Repair One-year Results From a Prospective, Multicenter, Blinded Randomized Controlled Trial

Journal

ANNALS OF SURGERY
Volume 273, Issue 6, Pages 1076-1080

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/SLA.0000000000004795

Keywords

laparoscopic; patient-centered outcomes; randomized controlled trial; robotic; ventral hernia

Categories

Funding

  1. Intuitive Surgical

Ask authors/readers for more resources

In this study, no significant differences were found in clinical outcomes between robotic and laparoscopic ventral hernia repair at 1-year postoperative. Both groups reported improvements in functional status, pain scores, and satisfaction levels. Further research is needed to validate these findings.
Objective: The aim of this study was to compare clinical and patient-reported outcomes of robotic versus laparoscopic ventral hernia repair (LVHR) at 1-year postoperative. Summary of Background Data: Despite a relative lack of research at low risk for bias assessing robotic ventral hernia repair (RVHR), the growth of RVHR has been rapid. We previously reported short-term results of the first randomized control trial comparing RVHR versus LVHR; there was no clear difference in clinical outcomes but increased operative time and cost with robotic repair. Methods: Patients from a multicenter, blinded randomized control trial comparing RVHR versus LVHR were followed at 1 year. Outcomes included wound complication (surgical site infection, surgical site occurrence, wound dehiscence), hernia occurrence including recurrence and port site hernia, readmission, reoperation, and patient-reported outcomes (functional status, pain, and satisfaction with repair and cosmesis). Results: A total of 124 patients were randomized and 113 patients (91%; 60 robot, 53 laparoscopic) completed 1-year follow-up. Baseline demographics were similar in both groups. No differences were seen in wound complication (15% vs 15%; P = 0.899), hernia recurrence (7% vs 9%; P = 0.576), or readmission (2% vs 6%; P = 0.251). No patients underwent reoperation in the robotic arm, whereas 5 (9%) did in the laparoscopic arm (P = 0.020). No differences were seen in patient-reported outcomes. Both arms reported clinically significant improvements in functional status, low pain scores, and high satisfaction scores at 1-year post repair. Conclusion: This study confirms that robotic ventral hernia repair is safe when compared to laparoscopy. Further studies are needed to confirm these findings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available