4.7 Article

Fabrication of target specific solid-state optical sensors using chromoionophoric probe-integrated porous monolithic polymer and silica templates for cobalt ions

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 413, Issue 12, Pages 3177-3191

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-021-03255-1

Keywords

Porous materials; Silica; Polymer; Optical; Cobalt sensor

Funding

  1. SERB [SB/FT/CS-051/2014]
  2. VIT (Institute Seed Grant 2019)

Ask authors/readers for more resources

The study demonstrates the design of two solid-state sensors for capturing ultra-trace Co(II) ions using porous monolithic silica and polymer templates, providing exclusive ion-selectivity and sensitivity with a rapid detection time of <= 5 min. The sensors exhibit excellent Co(II) detection limits and high efficiency in capturing Co(II) ions in industrial wastewater and spent Li-ion batteries, showcasing their potential for practical applications in environmental monitoring and resource recovery.
The article demonstrates the design of two solid-state sensors for the capturing of industrially relevant ultra-trace Co(II) ions using porous monolithic silica and polymer templates. The mesoporous silica reveals high surface area and voluminous pore dimensions that ensures homogeneous anchoring of 4-((5-(allylthio)-1,3,4-thiadiazol-2-yl)diazenyl)benzene-1,3-diol, as the chromoionophore. We report a first of its kind solid-state macro-/meso-porous polymer monolithic optical sensor from a monomeric chromoionophore, i.e., 2-(4-butylphenyl)diazenyl)-2-hydroxybenzylidene)hydrazine-1-carbothioamide. The monolithic solid-state sensors are characterized using HR-TEM-SAED, FE-SEM-EDAX, p-XRD, XPS, Si-29/C-13 CPMAS NMR, FT-IR, TGA, and BET/BJH analysis. The electron microscopic images reveal a highly ordered hexagonal mesoporous network of honeycomb pattern for silica monolith, and a long-range macroporous framework with mesoporous channels for polymer monolith. The sensors offer exclusive ion-selectivity and sensitivity for trace cobalt ions, through a concentration proportionate visual color transition, with a response kinetics of <= 5 min. The optimization of ion-sensing performance reveals an excellent detection limit of 0.29 and 0.15 ppb for Co(II), using silica- and polymer-based monolithic sensors, respectively. The proposed sensors are tested with industrial wastewater and spent Li-ion batteries, which reveals a superior cobalt ion capturing efficiency of >= 99.2% (RSD: <= 2.07%).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available