4.5 Article

Preparation and Characterization of Au/NiPc/Anti-p53/BSA Electrode for Application as a p53 Antigen Sensor

Journal

CHEMOSENSORS
Volume 9, Issue 1, Pages -

Publisher

MDPI
DOI: 10.3390/chemosensors9010017

Keywords

tumor suppressor protein; nickel phthalocyanine; p53 protein; differential pulse voltammetry; cyclic voltammetry; cancer biomarker

Funding

  1. Ministry of Science and Technology of the Republic of China [MOST 109-2221-E-182-012, MOST 107-2221-E-182-019]
  2. Chang Gung Memorial Hospital
  3. Chang Gung University [BMRP 576]

Ask authors/readers for more resources

The tumor suppressor protein p53 plays a crucial role in regulating cell cycle and apoptosis, with potential implications for cancer prevention. This study demonstrates the use of a modified electrode for detecting p53 antigen, offering promising clinical applications.
While the tumor suppressor protein p53 regulates the cell cycle to prevent cell damage, it also triggers apoptosis and prevents cancer. These inhibitory functions may disappear once the p53 gene is mutated. Under these circumstances, the detection of p53 protein concentrations can have significant clinical applications. In this study, nickel phthalocyanine (NiPc) was coated on a gold electrode to produce a modified Au/NiPc electrode. p53 antibodies were bonded to the Au/NiPc electrode by the Ni+2 ion in NiPc, which can be self-assembled with the imidazole group of the p53 protein. The Au/NiPc/anti-p53 electrode was subsequently dripped with a buffer solution of bovine serum albumin (BSA) to form the Au/NiPc/anti-p53/BSA electrode, which was used for the detection of p53 antigen under 10 mM potassium ferricyanide/potassium ferrocyanide (K3Fe(CN)(6)/K4Fe(CN)(6)) solution by cyclic voltammetry and differential pulse voltammetry analyses. The linear detection range and the sensitivity for the p53 antigen were 0.1-500 pg/mL and 60.65 mu A/Log (pg/mL)-cm(2), respectively, with a detection time of 90-150 s. In addition, Au/NiPc/anti-p53 (100 ng/mL)/BSA electrodes were tested for specificity using glucose, bovine serum albumin, histidine, ascorbic acid, uric acid, prostate-specific antigen, human serum albumin, and human immunoglobulin G. All p-values were <0.0005, indicating an outstanding specificity.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available