4.3 Article

Simulated twin-phase pancreatic CT generated using single portal venous phase dual-energy CT acquisition in pancreatic ductal adenocarcinoma

Journal

ABDOMINAL RADIOLOGY
Volume 46, Issue 6, Pages 2610-2619

Publisher

SPRINGER
DOI: 10.1007/s00261-020-02921-9

Keywords

Multidetector computed tomography; Pancreatic cancer; Radiation dosage

Ask authors/readers for more resources

Low keV images generated from a PVP DECT acquisition enable the creation of a twin-phase pancreatic protocol CT with comparable diagnostic accuracy for detecting PDAC, with a significant reduction in radiation dose. Reduced radiation dose is desirable in surveillance and screening for pancreatic diseases.
Purpose To evaluate the diagnostic performance of a simulated twin-phase pancreatic protocol CT generated from a single portal venous phase (PVP) dual-energy CT (DECT) acquisition in patients with pancreatic ductal adenocarcinoma (PDAC). Methods In this retrospective study, we included 63 patients with PDAC who underwent pancreatic protocol (pancreatic phase [PP] and PVP) DECT. Two data sets were created from this original acquisition-(1) Standard protocol (50 keV PP/65 keV PVP) and (2) Simulated protocol (40 keV/65 keV PVP). Using a 5-point scale, three readers scored image quality, tumor conspicuity, and arterial involvement by the PDAC. Signal-to-noise ratio (SNR) of the pancreas and tumor-to-pancreas contrast-to-noise ratio (CNR) were calculated. Qualitative scores, quantitative parameters, and radiation dose were compared between standard and simulated protocols. Results No significant difference in detection rate of PDAC was seen between the standard (58/63, 92.1%) and simulated protocols (56/63, 88.9%) (P = 0.76). Subjective scoring for arterial involvement for celiac (P = 0.86), superior mesenteric (P = 0.88), splenic (P = 0.86), common hepatic (P = 0.52), gastroduodenal (P = 0.95), first jejunal (P = 0.48) arteries, and aorta (P = 1.00) were comparable between two protocols. The image quality (P = 0.14), the SNR of the pancreas (P = 0.15), and CNR (P = 0.54) were comparable between two protocols. The projected mean dose-length product (DLP) (629.6 +/- 148.3 mGy cm) in the simulated protocol showed a 44% reduction in radiation dose compared to the standard protocol (mean DLP, 1123.3 +/- 268.9 mGy cm) (P < 0.0001). Conclusions Low keV images generated from a PVP DECT acquisition allows creation of a twin-phase pancreatic protocol CT with comparable diagnostic accuracy for detecting PDAC with significant reduction in radiation dose. Reduced radiation dose is desirable in surveillance and screening for pancreatic diseases.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available