4.6 Article

Self-Assembling Allochroic Nanocatalyst for Improving Nanozyme-Based Immunochromatographic Assays

Journal

ACS SENSORS
Volume 6, Issue 1, Pages 220-228

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acssensors.0c02148

Keywords

in vitro diagnostics; allochroic nanoparticles; oxidation activity; lateral flow assay; cardiac biomarker

Funding

  1. Life Science and Applied Solution Business at the Immuno Diagnostics Division, Biomonitoring, Evergreen system, Inc.
  2. Washington State University

Ask authors/readers for more resources

Paper-based rapid diagnostic tests are valuable alternatives for biomarker detection, but require further refinement. The integration of self-assembling allochroic nanocatalysts can improve the analytic sensitivity of these tests. The successful utilization of SANs in LFA-based biomarker detection may inspire integration of similar nanocatalysts into immunochromatographic testing methods.
Paper-based rapid diagnostic tests, such as immunochromatographic assays, namely lateral flow immunoassay (LFA), are valuable alternatives for biomarker detection compared to traditional laboratory-based tests, but these assays need further refinement to consolidate their biosensing capabilities. Nanozyme integration into LFA systems may provide a reliable means of improving the analytic sensitivity of LFA tests. Due to the involvement of multiple liquid-handling steps, the quantitative accuracy is compromised, hence hindering the use of untrained personnel point-of-care use. Self-assembling allochroic nanocatalyst (SAN) assemblies satisfy these LFA quality measures by optimizing analyte-antibody reporting performance and by intrinsically catalyzing chromogen activation, thereby reducing the number of liquid handling steps involved during sample analysis. In SANs, the hydrophobic chromogens serve as peroxidase substrates that self-assemble into nanoparticles at high loading fractions. These features demonstrate the potential for SAN-LFAs to be a valuable patient point-of-care (POC) test. Herein, we describe the SAN fabrication process and employ SAN-LFAs to detect cardiac troponin I-troponin C (cTnI-TnC) and myoglobin (Myo) levels present in plasma samples. Using SAN-LFAs, the limits of detection for cTnI-TnC and Myo were 0.012 ng/mL and 0.2 ng/mL respectively. We also demonstrate SAN compatibility with blood samples and stability under long-term storage conditions. The successful utlization of SANs in LFA-based biomarker detection may inspire these nanocatalysts to be integrated into similar immunochromatographic testing methods.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available