4.6 Article

Nonlinear Dynamic Response of a Precast Concrete Building to Sudden Column Removal

Journal

APPLIED SCIENCES-BASEL
Volume 11, Issue 2, Pages -

Publisher

MDPI
DOI: 10.3390/app11020599

Keywords

progressive collapse; sudden column removal; precast concrete; nonlinear dynamic analyses

Ask authors/readers for more resources

The study focuses on the progressive collapse resistance of a precast concrete (PC) frame building, analyzing the fundamental roles played by beam-to-column connection strength and tying reinforcement in such structures.
Robustness of reinforced concrete (RC) structures is an ongoing challenging research topic in the engineering community. During an extreme event, the loss of vertical load-bearing elements can activate large-deformation resisting mechanisms such as membrane and catenary actions in beams and floor slabs of cast-in-situ RC buildings to resist gravity loads. However, few studies have been conducted for precast concrete (PC) buildings, especially focused on the capacity of such structures to withstand column loss scenarios, which mainly relies on connection strength. Additional resistance resource and alternate load paths could be reached via tying systems. In this paper, the progressive collapse resistance of a PC frame building is analyzed by means of nonlinear dynamic finite element analyses focusing on the fundamental roles played by beam-to-column connection strength and tying reinforcement. A simplified modelling approach is illustrated in order to investigate the response of such a structural typology to a number of sudden column-removal scenarios. The relative simplicity of the modelling technique is considered useful for engineering practice, providing new input for further research in this field.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available