4.6 Article

Real-time ventilation control based on a Bayesian estimation of occupancy

Journal

BUILDING SIMULATION
Volume 14, Issue 5, Pages 1487-1497

Publisher

TSINGHUA UNIV PRESS
DOI: 10.1007/s12273-020-0746-7

Keywords

occupancy estimation; Bayesian MCMC; carbon dioxide; ventilation control

Funding

  1. Basic Science Research Program through the NRF - Ministry of Education [2016R1D1A1B0-1009625]
  2. Kookmin University

Ask authors/readers for more resources

This study investigates the performance of occupancy-based DCV schemes compared to time-based and CO2-based schemes, by utilizing the Bayes theorem for real-time control of ventilation rate. The study shows that occupancy-based schemes can successfully provide continuous control of ventilation rates without causing recursive problems. Additionally, time delays associated with the control procedure such as dispersion time, sensor-response time, and data processing time were discussed. The proposed approach, based on both occupancy and floor area, was found to provide the best conformity to the ASHRAE standard among the analyzed schemes.
Demand-controlled ventilation (DCV) is commonly implemented to provide variable amounts of outdoor air according to an internal ventilation demand. The objective of the present study is to investigate the applicability and the performance of occupancy-based DCV schemes in comparison with time-based and CO2-based DCV schemes. To do this, we apply the occupancy estimation method by the Bayes theorem to control the ventilation rate of an office building in real-time. We investigated six cases in total (two cases for each control scheme). Experiments were conducted in a small office room with controllable ventilation equipment and relevant sensors. The observed results indicated that the occupancy-based schemes relying on Bayes theorem could be applied successfully to perform continuous control of ventilation rates without causing recursive problems. Additionally, we discussed the time delays associated with the control procedure, including dispersion time, sensor-response time, and data processing time. Finally, we compared the performance of the proposed approach in six DCV cases in terms of a resultant indoor CO2 level and the total ventilation-air volume. We concluded that DCV control based on both occupancy and floor area provided the best conformity to the ASHRAE standard among the analyzed schemes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available