4.1 Article

Repeat patient testing-based quality control shows promise for use in veterinary biochemistry testing

Journal

VETERINARY CLINICAL PATHOLOGY
Volume 49, Issue 4, Pages 590-606

Publisher

WILEY
DOI: 10.1111/vcp.12921

Keywords

analytical error; control limit; QC validation; RPT; statistical QC

Funding

  1. Department of Biomedical and Diagnostic Sciences Fund for Educational Advancement and Research

Ask authors/readers for more resources

Background Repeat patient testing-based quality control (RPT-QC) is a form of statistical QC and an alternative to commercial quality control materials (QCM). Objective This study investigated the suitability of canine heparinized plasma for use in RPT-QC and assessed the predicted performance of RPT-QC for the detection of analytical error in chemistry testing. Methods The stability of canine plasma for RPT-QC was investigated via storage at two temperatures for three or six time points. Storage data were analyzed using repeated measures ANOVA and by comparing results for stored specimens to baseline data using predetermined criteria. To generate RPT-QC limit-setting and -validation data, leftover plasma was prospectively measured. Once control limits were established, these were challenged by measuring specimens for which the repeat aliquot had been manipulated to mimic analytical error. Finally, the predicted performance of RPT-QC and QCM-QC with four control rules was investigated using Westgard's EZ Rules 3. Results Refrigerated storage of canine plasma for 7 days allowed mild changes facilitating RPT-QC. RPT-QC limits for 12 of 17 common measurands were validated. Validated limits successfully flagged differences from manipulated specimen pairs as error. The predicted performance of RPT-QC for analytical error detection (represented by smallest achievable allowable total error, given a probability of error detection >= 85% and a probability of false rejection <= 5%) for four common control rules is comparable to that of QCM-QC. Conclusions This study provides evidence that RPT-QC using canine heparinized plasma refrigerated for 7 days can be used with simple control rules and low numbers of control materials, suggesting RPT-QC is applicable to both reference and in-clinic laboratory settings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available