4.7 Article

A Label-free DNA-based Fluorescent Sensor for Cisplatin Detection

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 326, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2020.128764

Keywords

Cisplatin; Thioflavin T; G-quadruplex; Label-free sensor

Funding

  1. Thailand Research Fund, Prince of Songkla University
  2. Faculty of Science, Prince of Songkla University [BRG6080009]
  3. Center of Excellence for Innovation in Chemistry (PERCH-CIC)
  4. Ministry of Higher Education, Science, Research and Innovation

Ask authors/readers for more resources

A label-free and sensitive fluorescent sensor based on Gquadruplex and Thioflavin T was developed for cisplatin detection in urine samples, showing high accuracy and precision. The sensor performance was influenced by various parameters including pH, buffer concentration, type and number of GQ, with a linear dynamic range of 10-500 nM. The sensor successfully quantified cisplatin levels with a limit of quantification at 10 nM.
Cisplatin, an anti-cancer drug, has been used extensively and has become a gold standard treatment for various types of cancer. However, overdosage has serious side effects. Thus, this drug should not be over-administered. The current study presents a label-free but sensitive fluorescent sensor for cisplatin detection based on Gquadruplex (GQ) and fluorescent dye Thioflavin T (ThT). In the absence of cisplatin, ThT binds to GQ, resulting in high fluorescence emission. In the presence of cisplatin, the GQ structure is destroyed after cisplatin-DNA adduct formation, leaving no binding scaffold for ThT, thereby causing a decrease in ThT fluorescence. The amount of cisplatin can be quantified from the changes in ThT fluorescence intensity. Parameters that affect the sensor performance were tested, including pH and concentration of potassium phosphate buffer, type of GQ, number of quartets, loop length, incubation time, and temperature. The sensor provided a linear dynamic range of 10-500 nM with limit of quantification at 10 nM. The sensor was successfully applied to detect cisplatin in urine samples from patients undergoing treatment with high accuracy (recoveries between 74 +/- 14 and 112.8 +/- 5.0%) and precision (relative standard deviations between 1.15% and 2.12%).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available