4.2 Article

Comparative Performance of Lateral Wall and Perimodiolar Cochlear Implant Arrays

Journal

OTOLOGY & NEUROTOLOGY
Volume 42, Issue 4, Pages 532-539

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MAO.0000000000002997

Keywords

Cochlear implantation; Electrode design; Lateral wall; Musical perception; Perimodiolar; Speech perception

Funding

  1. Advanced Bionics

Ask authors/readers for more resources

The physical shape of cochlear implant arrays can impact hearing outcomes, with perimodiolar designs showing superior speech perception in the first 6 months post-implantation compared to lateral wall electrodes, and equalizing performance by 24 months. Perimodiolar arrays also demonstrate superior melody perception compared to lateral wall designs.
Objective: The physical shape of cochlear implant (CI) arrays may impact hearing outcomes. The goal of this study was to compare post-operative speech and melody perception between patients with lateral wall (LW) and perimodiolar (PM) electrode arrays across a range of lengths and manufacturers. Study Design: Retrospective chart review. Setting: Tertiary Care Hospital. Patients: 119 adult patients with post-lingual hearing loss who underwent cochlear implantation. Main Outcome Measures: A total of seven different electrodes were evaluated including 5 different LW electrodes (CI422 [Cochlear American], 1J [Advanced Bionics], Medium [Med El], Standard [Med El], Flex28 [Med El]) and 2 PM electrodes (Contour [Cochlear American], MidScala [Advanced Bionics]). Speech perception outcomes (n = 119 patients) were measured by Consonant-Nucleus-Consonant (CNC) scores collected 3, 6, 12 and 24 months after implantation. Melody perception outcomes (n = 35 CI patients and n = 6 normal hearing patients) were measured by Melodic Contour Identification (MCI). Results: CNC scores increased over time after implantation across all array designs. PM designs exhibited higher CNC scores compared to LW electrodes, particularly 6-months after implantation. Pre-operative pure tone averages did not correlate with post-operative CNC scores. PM arrays outperformed LW electrodes in terms of MCI scores. Conclusions: The physical shape of cochlear implant electrode arrays may impact hearing performance. Compared to LW designs, PM arrays appear to offer superior speech perception during the first 6 months after implantation, with performance equalizing between groups by 24 months. Compared to LW designs, PM arrays also appear to afford superior melody perception.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available