4.7 Article

Implementation of a 4Pi-SMS super-resolution microscope

Journal

NATURE PROTOCOLS
Volume 16, Issue 2, Pages -

Publisher

NATURE RESEARCH
DOI: 10.1038/s41596-020-00428-7

Keywords

-

Funding

  1. John Fell Fund [141/144]
  2. Wellcome Trust [105605/Z/14/Z, 107457/Z/15/Z, 095927/B/11/Z, 203285/Z/16/Z, 203285/B/16/Z, 203144/Z/16/Z, 203285/C/16/Z, 095927/A/11/Z]
  3. National Institutes of Health (NIH) [R01 GM118486]
  4. NIH [T32EB019941]
  5. Engelhorn Foundation
  6. European Research Council - EMBL [ERC CoG-724489]
  7. 4D Nucleome/4DN NIH Common Fund [U01 EB021223]
  8. EMBL Interdisciplinary Postdoc Programme (EIPOD) under Marie Curie Actions COFUND
  9. Southern University of Science and Technology, China
  10. European Research Council [AdOMIS 695140]
  11. Wellcome Trust [203285/Z/16/Z, 095927/B/11/Z] Funding Source: Wellcome Trust

Ask authors/readers for more resources

The development of single-molecule switching (SMS) fluorescence microscopy has allowed researchers to observe cell structures at unprecedented resolution. This protocol aims to guide interested researchers in establishing super-resolution microscopy in their laboratories. The process involves assembling the instrument, testing its performance, preparing test samples, acquiring images, and analyzing raw data to reconstruct 3D datasets.
The development of single-molecule switching (SMS) fluorescence microscopy (also called single-molecule localization microscopy) over the last decade has enabled researchers to image cell biological structures at unprecedented resolution. Using two opposing objectives in a so-called 4Pi geometry doubles the available numerical aperture, and coupling this with interferometric detection has demonstrated 3D resolution down to 10 nm over entire cellular volumes. The aim of this protocol is to enable interested researchers to establish 4Pi-SMS super-resolution microscopy in their laboratories. We describe in detail how to assemble the optomechanical components of a 4Pi-SMS instrument, align its optical beampath and test its performance. The protocol further provides instructions on how to prepare test samples of fluorescent beads, operate this instrument to acquire images of whole cells and analyze the raw image data to reconstruct super-resolution 3D data sets. Furthermore, we provide a troubleshooting guide and present examples of anticipated results. An experienced optical instrument builder will require similar to 12 months from the start of ordering hardware components to acquiring high-quality biological images.