4.7 Article

Assessment of the structural conditions in steel pipeline under various operational conditions - A machine learning approach

Journal

MEASUREMENT
Volume 166, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.measurement.2020.108262

Keywords

Pipe condition monitoring; Structural health monitoring; Fiber optic sensing; Machine learning

Funding

  1. University Research Board at the American University of Beirut [103604]

Ask authors/readers for more resources

Oil and water transport pipeline systems are susceptible to damage due to harsh environmental conditions and operational factors. Hence, ongoing maintenance and inspection are required. The development of continuous and reliable monitoring will ensure the safe usage of these structures and assist in the extension of their life spans. In this study, the monitoring and assessment of pipelines are performed using a network of Fiber Bragg Grating (FBG) sensors mounted in the longitudinal and circumferential directions pipelines. The sensitivity of these measurements to assess pipe pressure and flow variations, and leakage detection and localization were evaluated. Water, at a controlled pressure and flow rate, was pumped into the designed 6-m pipe testbed. Leakage was simulated by opening one of the four designated valves installed on the pipe. Support Vector Machine (SVM) algorithms were implemented, using the collected data, to assist in the prediction of the structural condition of the pipe under various operational conditions. Pressure variations inside the pipe highly impacted the amplitude of the measured strain, increasing it significantly up to 20%. A flow rate increase of 5 GPM had the inverse effect, resulting in a 5% decrease in the amplitude of the measured strain. A change of leakage hole size greatly influenced the measured signal, resulting in a 55% change in amplitude between a 2-cm(2) and a 5-cm(2) hole. To determine the leakage location, only the temporal aspects of the signal were affected, resulting in slight shifts in sensor response times. The developed SVM classifiers reached accuracies of 88% for flow rate classification, greater than 95% for pressure classification, and 100% for leakage size classification. The accuracy of leakage localization did not exceed 72%. These results are promising for the monitoring of the structural conditions related to leakage detection and localization, based on the patterns observed. (C) 2020 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available