4.7 Article

Effect of initial particle deposition rate on cake formation during dead-end microfiltration

Journal

JOURNAL OF MEMBRANE SCIENCE
Volume 618, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.memsci.2020.118672

Keywords

Membrane fouling; Network fouling model; Optical coherence tomography; Microfiltration; Particle deposition rate

Funding

  1. Singapore GSK (GlaxoSmithKline) - EDB (Economic Development Board) Trust Fund
  2. Singapore Ministry of Education Tier 1 Grant [2019-T1-002-065]

Ask authors/readers for more resources

A non-monotonic correlation between initial particle deposition rate and extent of flux decline was observed during dead-end microfiltration. The network fouling model and experimental OCT characterization explained the counter-intuitive flux decline trends, providing valuable insights towards understanding membrane fouling phenomena.
The relationships between various parameters and membrane fouling are generally well-established in micro-filtration. Surprisingly, a non-monotonic correlation between initial particle deposition rate and extent of flux decline was observed during dead-end microfiltration. To understand the underlying mechanism, a fouling model and three-dimensional optical coherence tomography (OCT) scanning were employed. Four different initial deposition rates were imposed using latex particles (3 mu m) as the model foulant and polycarbonate track-etched membrane (pore size = 2 mu m). The network fouling model revealed that, as the initial deposition rate increased, (i) the probability of deposition on the non-porous part of the membrane (beta) increased then decreased; (ii) the initial cake resistance (R-c0) increased monotonically; and (iii) the specific cake resistance (R'c) decreased then increased. The OCT image analysis further informed that (i) the deposited foulants tended to form larger clusters at the lowest and highest initial deposition rates of 12.5 and 31.25 g/m(2)/h, respectively, but tended to be more dispersed at the intermediate initial deposition rate of 25 g/m(2)/h; and (ii) the more significant specific cake resistances (R'(c)) at the lowest and highest initial deposition rates were due to denser cakes stemming from greater particle rearrangement within the cake and greater particle concentration near the membrane, respectively. The network fouling model and experimental OCT characterization served to explain the counter-intuitive flux decline trends, and the insights are valuable towards better understanding of the inevitable membrane fouling phenomena.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available