4.0 Article

Comparison between superior vena cava ablation in addition to pulmonary vein isolation and standard pulmonary vein isolation in patients with paroxysmal atrial fibrillation with the cryoballoon technique

Journal

Publisher

SPRINGER
DOI: 10.1007/s10840-020-00932-6

Keywords

Superior vena cava isolation; Paroxysmal atrial fibrillation; Pulmonary vein isolation; Second-generation cryoballoon

Ask authors/readers for more resources

The study retrospectively evaluated the clinical impact of SVC isolation in addition to ordinary PVI in patients with PAF. The results showed that the combination of SVC and PV isolation may improve freedom from ATs compared to PVI alone at 1-year follow-up.
Background Paroxysmal atrial fibrillation (PAF) can be triggered by non-pulmonary vein foci, like the superior vena cava (SVC). The latter is correlated with improved result in terms of freedom from atrial tachycardias (ATs), when electrical isolation of this vessel utilizing radiofrequency energy (RF) is achieved. Objectives Evaluate the clinical impact, in patients with PAF, of the SVC isolation (SVCi) in addition to ordinary pulmonary vein isolation (PVI) by means of the second-generation cryoballoon (CB) Methods A total of 100 consecutive patients that underwent CB ablation for PAF were retrospectively selected. Fifty consecutive patients received PVI followed by SVCi by CB application, and the following 50 consecutive patients received standard PVI. All patients were followed 12 months. Results The mean time to SVCi was 36.7 +/- 29.0 s and temperature at SVC isolation was - 35 (- 18 to - 40) degrees C. Real-time recording (RTR) during SVCi was observed in 42 (84.0%) patients. At the end of 12 months of follow-up, freedom from ATs was achieved in 36 (72%) patients in the PVI only group and in 45 (90%) patients of the SVC and PV isolation group (Fisher's exact test p = 0.039, binary logistic regression: p = 0.027, OR = 0.28, 95%CI = 0.09-0.86). In survival analysis, SVC and PV isolation group was also associated with improved freedom from ATs (log-rank test: p = 0.017, Cox regression: p = 0.026, HR = 0.31, 95%CI = 0.11-0.87). Conclusion Superior vena cava isolation with the CB in addition to PVI might improve freedom from ATs if compared to PVI alone at 1-year follow-up.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available