4.4 Article

Tendon-like tether formation for tongue-base advancement in an ovine model using a novel implant device intended for the surgical management of obstructive sleep apnoea

Publisher

WILEY
DOI: 10.1002/jbm.b.34765

Keywords

apnoea; collagen; polyurethane(s); tendon prosthesis; tongue

Funding

  1. Technology Innovation Agency (TIA) of South Africa

Ask authors/readers for more resources

Obstructive sleep apnoea is a serious condition affecting nearly one billion adults globally, with CPAP being the gold standard treatment. A study on tongue tethering devices implanted in sheep showed a hybrid biological tendon-like tether formed after 32 weeks, with a break-strength of 60 N exceeding the force needed to prevent upper airway collapse.
Obstructive sleep apnoea (OSA) is a serious debilitating condition with significant morbidity and mortality affecting almost one billion adults globally. The current gold standard in the non-surgical management of airway collapse is continuous positive airway pressure (CPAP). However, non-compliance leads to a high abandon rate (27-46%). While there are multiple sites of airway obstruction during sleep, the tongue base is recognized as the key player in the pathogenesis of OSA. Poor outcomes of current tongue suspension devices are due to fracture, slippage or migration of devices. Three tongue tethering device groups, namely a polydioxanone/polyurethane combination (PDO + PU) treatment group, a PDO analytical control group, and a polypropylene (PP) descriptive control group, were implanted into 22 sheep (75-85 kg) in a two-phased study. After implant times of 8, 16, and 32 weeks, sheep were serially euthanized to allow for explantation of their tongues and chins. The PDO + PU devices remodeled during the 32-week implant period into a hybrid biological tendon-like tether through the process of gradual degradation of the PDO and collagen deposition as shown by electrophoresis, histology and mechanical testing. The control PDO device degraded completely after 32 weeks and the PP devices remained intact. The hybrid biological tendon-like tether exhibited a break-strength of 60 N, thus exceeding the maximum force to overcome upper airway collapse.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available