A novel dual-temperature ejector-compression heat pump cycle-exergetic and economic analyses

Journal

INTERNATIONAL JOURNAL OF REFRIGERATION
Volume 126, Issue -, Pages 155-167

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2021.01.005

Keywords

Dual-temperature; Ejector; Exergy efficiency; Air-source heat pump; Economic; Eco-friendly refrigerants

Funding

  1. National Natural Science Foundation of China [51878585]

Ask authors/readers for more resources

The study focuses on the performance of a dual-temperature ejector-compression air-source heat-pump system. The enhanced DAHP-II performs significantly better than DAHP-I, with R290 identified as the most suitable refrigerant.
High-efficiency air source heat pumps are of great importance for energy saving and environmental protection, especially for the cold area in north China. In this study, the thermo-economic performance of the dual-temperature ejector-compression air-source heat-pump (DAHP) cycle, is conducted wherein R1234yf, R290, and R134a are used as refrigerants. Two configurations are examined: DAHP-I (without an ejector, conventional system for comparison) and DAHP-II (enhanced by an ejector). The effects of the principal operating parameters on the system performance, including the exergy destruction (Ex(d_tot)), exergy efficiency (eta(ex _sys)) and economic, are investigated, and the two systems are compared. The results indicate that the DAHP-II significantly outperforms the DAHP-I in terms of Ex d_tot, eta(ex _sys) and economic index, and the R290 is the most suitable refrigerant applied for the DAHP-II system. Compared with DAHP-I, the Ex(d_tot) for DAHP-II is reduced by 24.0%-54.8%. For DAHP-II, although the refrigerant type affects Ex(d_tot) and eta(ex _sys) slightly, while the effect on economic is noticeable. Comparing with R1234yf, the system using the R134a and R290 as the working fluid, the total annual capital cost rate (eta C tot) can be reduced by 6.2% and 11.0% respectively. Besides, the DAHP-II outperforms the DAHP-I system significantly with the R134a, R290 and R1234yf as refrigerant in terms of economic. The relative decrease ratio in total annual capital cost rate (.C tot) are 21.6%, 13.5% and 24.0% respectively. This study provides a basis for the application of DAHP system. (C) 2021 Elsevier Ltd and IIR. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available