4.7 Article

Day-and-Night Closed-Loop Glucose Control in Patients With Type 1 Diabetes Under Free-Living Conditions: Results of a Single-Arm 1-Month Experience Compared With a Previously Reported Feasibility Study of Evening and Night at Home

Journal

DIABETES CARE
Volume 39, Issue 7, Pages 1151-1160

Publisher

AMER DIABETES ASSOC
DOI: 10.2337/dc16-0008

Keywords

-

Funding

  1. European Commission [FP7-ICT-2009-4, 247138]

Ask authors/readers for more resources

OBJECTIVE After testing of a wearable artificial pancreas (AP) during evening and night (E/N-AP) under free-living conditions in patients with type 1 diabetes (T1D), we investigated AP during day and night (D/N-AP) for 1 month. RESEARCH DESIGN AND METHODS Twenty adult patients with T1D who completed a previous randomized crossover study comparing 2-month E/N-AP versus 2-month sensor augmented pump (SAP) volunteered for 1-month D/N-AP nonrandomized extension. AP was executed by a model predictive control algorithm run by a modified smartphone wirelessly connected to a continuous glucose monitor (CGM) and insulin pump. CGM data were analyzed by intention-to-treat with percentage time-in-target (3.9-10 mmol/L) over 24 h as the primary end point. RESULTS Time-in-target (mean +/- SD, %) was similar over 24 h with D/N-AP versus E/N-AP: 64.7 +/- 7.6 vs. 63.6 +/- 9.9 (P = 0.79), and both were higher than with SAP: 59.7 +/- 9.6 (P = 0.01 and P = 0.06, respectively). Time below 3.9 mmol/L was similarly and significantly reduced by D/N-AP and E/N-AP versus SAP (both P < 0.001). SD of blood glucose concentration (mmol/L) was lower with D/N-AP versus E/N-AP during whole daytime: 3.2 +/- 0.6 vs. 3.4 +/- 0.7 (P = 0.003), morning: 2.7 +/- 0.5 vs. 3.1 +/- 0.5 (P = 0.02), and afternoon: 3.3 +/- 0.6 vs. 3.5 +/- 0.8 (P = 0.07), and was lower with D/N-AP versus SAP over 24 h: 3.1 +/- 0.5 vs. 3.3 +/- 0.6 (P = 0.049). Insulin delivery (IU) over 24 h was higher with D/N-AP and SAP than with E/N-AP: 40.6 +/- 15.5 and 42.3 +/- 15.5 vs. 36.6 +/- 11.6 (P = 0.03 and P = 0.0004, respectively). CONCLUSIONS D/N-AP and E/N-AP both achieved better glucose control than SAP under free-living conditions. Although time in the different glycemic ranges was similar between D/N-AP and E/N-AP, D/N-AP further reduces glucose variability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available