NEMA NU2-2012 performance measurements of the United Imaging uPMR790: an integrated PET/MR system

Journal

Publisher

SPRINGER
DOI: 10.1007/s00259-020-05135-9

Keywords

NEMA NU2-2012; Performance evaluation; PET; MR

Funding

  1. National Key Research and Development Plan Digital Diagnosis and Treatment Equipment Research and Development Key Specialty [2016YFC0103900]
  2. Shanghai Science and Technology Commission Science and Technology Innovation Action Plan in the Field of Cooperation in the Field of Industry, Education and Research [19DZ1930700]
  3. Shanghai Municipal Key Clinical Specialty [shslczdzk03401]

Ask authors/readers for more resources

This study evaluated the PET performance of the third commercially available whole-body integrated PET/MR system. The measurement results showed comparable performance with other state-of-the-art PET/MR systems. Clinical scans revealed similar image quality between the PET/MR and PET/CT systems.
Purpose In this paper, we aimed to evaluate the positron emission tomography (PET) performance of, to the best of our knowledge, the third commercially available whole-body integrated PET/magnetic resonance (MR) system. Methods The PET system performance was measured following the NEMA standards with and without simultaneous MR operation. PET spatial resolution, sensitivity, scatter fraction, count-rate performance, accuracy of count losses and random corrections, image quality, and time-of-flight (TOF) resolution were quantitatively evaluated. Clinical scans were acquired at the PET/MR system and compared with images acquired at a PET/CT with the same digital detector technology. Results Measurement results of essential PET performance were reported in the form of MR idle (MR pulsing). The axial, radial, and tangential spatial resolutions were measured as 2.72 mm (2.73 mm), 2.86 mm (2.85 mm), and 2.81 mm (2.82 mm) FWHM, respectively, at 1 cm radial offset. The NECR peak was measured as 129.2 kcps (129.5 kcps) at 14.7 kBq mL(-1) (14.2 kBq mL(-1)). The scatter fraction at NECR peak was 37.9% (36.5%), and the maximum slice error below NECR was 4.1% (4.5%). Contrast recovery coefficients ranged from 51.8% (52.3%) for 10 mm hot sphere to 87.3% (87.2%) for 37 mm cold sphere. TOF resolution at 5.3 kBq mL(-1) was measured at 535 ps (540 ps). With point source, TOF was measured to be 474 ps (485 ps). Clinical scans revealed similar image quality from the PET/MR and the comparative PET/CT system. Conclusion The PET performance of the newly introduced integrated PET/MR system is not significantly affected by the simultaneous operation of an MR sequence (2-point DIXON sequence). Measurement results demonstrate comparable performance with other state-of-the-art PET/MR systems. The clinical benefits of high spatial resolution and long axial coverage remain to be further evaluated in specific clinical imaging applications.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available