4.4 Article

Motor unit action potential amplitude during low torque fatiguing contractions versus high-torque non-fatiguing contractions: a multilevel analysis

Journal

EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY
Volume 121, Issue 4, Pages 1145-1157

Publisher

SPRINGER
DOI: 10.1007/s00421-021-04606-7

Keywords

Motor unit recruitment; Surface EMG; Fatigue; Motor unit size

Ask authors/readers for more resources

The study compared the motor unit action potential (MUAP) amplitude at different torque levels and in fatigue conditions. Results showed that MUAP amplitude during a 30% MVC fatiguing protocol was comparable to that during a non-fatigued 80% MVC condition.
Purpose The ability to maintain an absolute, submaximal torque level during fatiguing contractions is controlled, in part, by the recruitment of larger motor units. These motor units are commonly identified based on greater action potential peak-to-peak amplitude values. It is unclear, however, if motor unit action potential (MUAP) amplitude values during low torque, fatiguing contractions reach similar levels as those observed during non-fatigued, high torque contractions. To establish a clearer understanding of motor unit control during fatigue, we compared MUAP amplitude during 50 and 80% maximum voluntary contraction (MVC) torque contractions and at the beginning, middle, and end of a 30% MVC fatigue protocol. Methods Eleven untrained men (mean age = 24 years) performed isometric contractions at 50 and 80% MVC, followed by repeated contractions at 30% MVC. Surface electromyographic (EMG) signals were detected from the vastus lateralis and decomposed to quantify the peak-to-peak amplitude of individual MUAPs. A two-level multilevel model was estimated, allowing examination of simultaneous measures of MUAP amplitude within participants and controlling for the dependence between measures within participants. Results Results from the multilevel analyses suggested that there were not statistically significant differences in MUAP amplitude between 80% MVC and end fatigue. Separate repeated-measures analyses of variance indicated that there were not statistically significant mean differences in greatest MUAP or surface EMG amplitude between 80% MVC and end fatigue. Conclusions MUAP and surface EMG amplitude values during a 30% MVC fatiguing protocol appear to be comparable to those observed during a non-fatigued 80% MVC condition.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available