4.4 Article

Effects of ozonation on disinfection by-product formation potentials and biostability in a pilot-scale drinking water treatment plant with micro-polluted water

Journal

ENVIRONMENTAL TECHNOLOGY
Volume 42, Issue 20, Pages 3254-3265

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/09593330.2020.1829083

Keywords

Micro-polluted source water; pilot-scale advanced drinking water treatment; ozonation; DBPFP; biostability

Funding

  1. National Science and Technology Major Project [2014ZX07405002]
  2. Ministry of Science and Technology of the People's Republic of China

Ask authors/readers for more resources

The study found that ozonation can effectively remove disinfection by-product formation potentials, with total removal rates reaching 77.3% and 57.0% for trihalomethane formation potentials (THMFPs) and haloacetic acid formation potentials (HAAFPs) respectively at an ozone dosage of 2 mg/L. Integrated advanced treatment processes can significantly suppress bromine in total THMFPs (TTHMFPs) and increase bromine in total HAAFPs (THAAFPs), resulting in higher brominated HAAFP proportions in treated water compared to raw water.
The accelerated urbanization in China has caused intensified micro-pollution problems for drinking water sources, severely challenging drinking water treatment efficiencies and its biostability. This study mainly investigated the effects of ozonation on disinfection by-product formation potentials (DBPFPs) and biological dissolved organic carbon (BDOC) in a pilot-scale ozonation-biological activated carbon advanced drinking water treatment plant with micro-polluted raw water. The results indicated that the micro-polluted water would be effectively treated in the advanced treatment processes with DBPFPs significantly eliminated. The total removal rates of trihalomethane formation potentials (THMFPs) and haloacetic acid formation potentials (HAAFPs) increased with the elevated ozone dosage to finally a relatively stable stage, and the maximum removal rates of 77.3% and 57.0%, respectively, were achieved at the ozone dosage of 2 mg/L. The bromine incorporation in total THMFPs (TTHMFPs) was dramatically suppressed after integrated advanced treatment processes, while that in total HAAFPs (THAAFPs) was promoted with the corresponding increment of up to 25.3% for bromine incorporation factor, which caused relatively high brominated HAAFP proportions in the treated water than in the raw water. In addition, the BDOC generation rate and THAAFP removal rate during the post-ozonation treatment displayed apparent positive correlation, and a similar relationship was observed for the BDOC degradation rate and TTHMFP removal rate during the BAC treatment in the studied ozone dosage (1 similar to 5 mg/L). The findings strongly implied a promising alternative to measure DBPFP removal rate instead of BDOC level for more sensitive and convenient monitoring of the biostability in the reclaimed water.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available