4.8 Article

Reusable, facile, and rapid aptasensor capable of online determination of trace mercury

Journal

ENVIRONMENT INTERNATIONAL
Volume 146, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.envint.2020.106181

Keywords

Biosensor; Evanescent wave; Mercury; Online monitoring; T-T mismatch

Funding

  1. Beijing Natural Science Foundation-Haidian Primitive Innovation Joint Fund Project [L182045]

Ask authors/readers for more resources

The homemade waveguide-based evanescent wave aptasensor demonstrated high selectivity and stability for the online monitoring of mercury pollution in water samples, with a detection limit of 0.2 μg/L and a linear range from 1.4 to 240.7 μg/L. The sensor's negligible environmental matrix effect and cross reactivity towards other metal ions ensured its reliability for real-time monitoring and emergency treatment of pollution incidents.
Herein, we reported a homemade waveguide-based evanescent wave aptasensor for the facile online monitoring of mercury pollution. The aptasensor exploited the high selectivity of hairpin structure-based thymidine-Hg2+-thymidine coordination chemistry (T-T mismatch) for Hg2+ recognition and the stably regenerable capability of DNA-functionalized waveguide surfaces. The presence of Hg2+ caused the T-T mismatch of Cy5.5-labeled T-rich single-stranded DNA sequences. The formed hairpin structures blocked the further hybridization of T-rich single-stranded DNA sequences with the complementary DNA strands that are modified on the waveguide surface; this phenomenon was accompanied by the decrease in the fluorescent signals excited by the evanescent wave. The limit of detection in real water samples was determined to be 0.2 mu g/L, which was comparable with that of 0.4 mu g/L in an ultrapure water under controlled conditions. And the linear range was observed from 1.4 mu g/L to 240.7 mu g/L. The negligible environmental matrix effect on the performance ensured the reliability of the proposed aptasensor. Moreover, the cross reactivity of this method toward other investigated metal ions was negligible. Through the delicate surface modification with DNA molecules covalently, the chip was reused at least 31 times with a relative standard deviation (RSD) of less than 19%. A Hg2+ pollution accident was successfully detected within 30 min, shedding new light in pollution monitoring, environment restoration, and emergency treatment.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available