Enzymatic glucose electrodes based on mediated electron transfer, with the inclusion of carbon nanosupports, can enhance characteristics such as current density and stability. However, large quantities of nanomaterials are often needed for significant effects. Grafting the enzyme to the surface of the carbon nanotubes improves dispersibility and enzyme activity, leading to optimised component amounts for increased current density and stability. Operational stability remains a challenge, with proposed methods for improvement including overcoating with a protective layer and implementing intermittent sampling of glucose levels.
Enzymatic glucose electrodes based on mediated electron transfer have potential for application as semi implantable or implantable sensors. Enzyme electrodes consisting of adsorbed osmium-based redox polymer crosslinked with a glucose oxidising enzyme are promising systems for continuous glucose monitoring, but suffer from signal output magnitude and long-term stability issues. The inclusion of carbon nanosupports such as multiwalled carbon nanotubes (MWCNTs) into these sensors tends to increase characteristics such as current density and surface coverage of enzyme or mediator. However, large quantities of nanomaterials are often necessary to see significant effects. Grafting of the enzyme to the surface of the MWCNTs improves dispersibility of the nanosupport aiding enzyme electrode fabrication, and increases enzyme activity. Here we report on a design of experiments (DoE) approach to determine the optimum amount of each component in enzyme electrodes, using glucose oxidase grafted to carbon nanotube support, to maximise current density and stability for application to continuous use glucose biosensing. Using the DoE approach while considering current density and stability responses delivers a set of component amounts where both responses are optimised. Thus far stability has not been investigated as a response to be optimised using a DoE approach. The optimised enzyme electrodes show a current density of 3.18 +/- 0.30 mA cm(-2), representing a 146% increase in current density in 50 mM phosphate-buffered saline at 37 degrees C containing 5 mM glucose when compared to similar systems where enzyme and nanosupport are not grafted to each other. Using the predictive DoE model, component amounts were then modified to minimise the quantity of the nanoconjugate while showing similar electrochemical behaviour and current density to the optimised system, using 93% less of the nanoconjugate. However, the operational stability under continuous use was moderate with only approximate to 50% amperometric current retained after 12 hr use. Overcoating with a Nafion protective layer improved stability to 72-75% over the same period. The coupling of adsorbed films to the electrode surface, use of additional perm-selective membranes, and/or use of pulsed potentials to implement intermittent sampling of glucose levels, rather than continuous amperometry, is proposed to improve operational stability. (C) 2021 The Authors. Published by Elsevier Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available