4.7 Article

Retinal layer segmentation in rodent OCT images: Local intensity profiles & fully convolutional neural networks

Journal

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.cmpb.2020.105788

Keywords

Optical coherence tomography; Rodent OCT; Rat OCT; Layer segmentation; Convolutional neural networks; Intensity profile

Funding

  1. Danish Animal Experimentation Council [2017-15-020101213]
  2. NVIDIA Corporation
  3. Horizon 2020, the European Union's Framework Programme for Research and Innovation [732613]
  4. Spanish Ministry of Economy and Competitiveness [DPI2016-77869]
  5. GVA [PROMETEO/2019/109]

Ask authors/readers for more resources

This study presented two different approaches to detect the most significant retinal layers in a rat OCT image, utilizing local intensity profiles and deep learning technology. Both approaches achieved satisfactory results on the rat OCT database, with the deep learning method outperforming the other. Additionally, the study demonstrated the superiority of the first approach over commercial image segmentation software.
Background and Objective: Optical coherence tomography (OCT) is a useful technique to monitor retinal layer state both in humans and animal models. Automated OCT analysis in rats is of great relevance to study possible toxic effect of drugs and other treatments before human trials. In this paper, two different approaches to detect the most significant retinal layers in a rat OCT image are presented. Methods: One approach is based on a combination of local horizontal intensity profiles along with a new proposed variant of watershed transformation and the other is built upon an encoder-decoder convolutional network architecture. Results: After a wide validation, an averaged absolute distance error of 3.77 +/- 2.59 and 1.90 +/- 0.91 mu m is achieved by both approaches, respectively, on a batch of the rat OCT database. After a second test of the deep-learning-based method using an unseen batch of the database, an averaged absolute distance error of 2.67 +/- 1.25 mu m is obtained. The rat OCT database used in this paper is made publicly available to facilitate further comparisons. Conclusions: Based on the obtained results, it was demonstrated the competitiveness of the first approach since outperforms the commercial Insight image segmentation software (Phoenix Research Labs) as well as its utility to generate labelled images for validation purposes speeding significantly up the ground truth generation process. Regarding the second approach, the deep-learning-based method improves the results achieved by the more conventional method and also by other state-of-the-art techniques. In addition, it was verified that the results of the proposed network can be generalized to new rat OCT images. (C) 2020 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available