4.5 Article

Does the type of endodontic access influence in the cyclic fatigue resistance of reciprocating instruments?

Journal

CLINICAL ORAL INVESTIGATIONS
Volume 25, Issue 6, Pages 3691-3698

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00784-020-03694-7

Keywords

Cyclic fatigue resistance; NiTi files; Minimally invasive access; Reciprocating instruments; Reciproc files

Funding

  1. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)
  2. Fundacao de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ)

Ask authors/readers for more resources

This study aimed to compare the cyclic fatigue resistance of Reciproc R25 and Reciproc Blue R25 instruments in traditional and ultraconservative endodontic access cavities. The results showed that R25B had significantly higher cyclic fatigue resistance than R25, but when used in ultraconservative access cavities, both instruments showed decreased resistance.
Introduction The aim of the present study was to compare the cyclic fatigue resistance of Reciproc R25 (R25) and Reciproc Blue R25 (R25B) instruments, after simulated clinical use in traditional (TradAC) and ultraconservative (UltraAC) endodontic access cavities. Methods Forty mandibular molars were randomly assigned into the following groups, according to the type of access and instrument to be used: TradAC and R25, TradAC and R25B, UltraAC and R25, and UltraAC and R25B. Teeth were accessed accordingly, and the root canals were prepared using RECIPROC ALL kinematics. The cyclic fatigue resistance of the forty used instruments was obtained measuring the time to fracture in an artificial stainless-steel canal. Ten brand new R25 and R25B were used as control groups. The fracture surfaces and the side cutting edges of the instruments were examined with a scanning electron microscope. Data were statistically analyzed using one-way ANOVA and post hoc Tukey tests with a significance level of P < 0.05. Results R25B instruments showed significantly higher cyclic fatigue resistance than R25, regardless of the access cavity type (P < 0.05). No differences were observed in the cyclic fatigue resistance between instruments without simulated clinical use and used in TradAC (P > 0.05). R25 and R25B used in UltraAC showed significantly lower cyclic fatigue resistance compared with the instruments used in TradAC and without simulated clinical use (P < 0.05). Conclusions R25B files showed improved cyclic fatigue resistance than R25. The use of R25B and R25 files in mandibular molars with UltraACs decreased their cyclic fatigue resistance, compared with TradAC.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available