4.7 Article

Levels of polychlorinated biphenyls (PCBs) in honeybees and bee products and their evaluation with ambient air concentrations

Journal

ATMOSPHERIC ENVIRONMENT
Volume 244, Issue -, Pages -

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.atmosenv.2020.117903

Keywords

Biomonitoring; Pollen/air partitioning; POPs; PCBs; Sources identification

Funding

  1. Scientific and Technologic Research Council of Turkey (TUBITAK) [116Y208]
  2. Commission of Scientific Research Projects of the Bursa Uludag University [OUAP (MH) 2014/22]

Ask authors/readers for more resources

This study compared the concentrations of PCBs measured by PASs and biomonitoring methods, finding similar distribution results. High molecular weight PCBs moved from air to pollen media, while low molecular weight PCB congeners passed from pollen media to air in both sampling areas.
Both quantitative and qualitative evaluation of pollutants can be achieved by biomonitoring, enabling the determination of persistent organic pollutants (POPs) with a natural substance. Similarly, passive air samplers (PASs) are among the commonly used methods for the determination of atmospheric POPs. However, in the literature, there are few studies in which both methods (Biomonitoring and PASs) are evaluated together. This study aims to determine the relationship between concentration values and sources of polychlorinated biphenyls (PCBs) measured by PASs and biomarkers (honeybee, honey, and pollen). The total concentrations of 50 PCB congeners (Sigma(50)PCBs) in PASs (n = 10) were 2259.63 +/- 647.18 pg m(3) for the urban area and 2685.65 +/- 708.45 pg m(3) for the semi-urban area. Sigma(50)PCBs in the honeybee (n = 10), honey (n = 7), and pollen (n = 10) samples were 114.44 +/- 20.36, 104.89 +/- 31.48 and 65.89 +/- 13.54 ng g(-1) dry weight (dw) for the urban sampling area, respectively, and 119.41 +/- 45.13, 112.75 +/- 21.57 and 46.52 +/- 8.85 ng g(-1) dw for the semi-urban sampling area, respectively. Similar homologous group distributions between biomarkers and PASs were obtained. The plant/air partitioning coefficient (K-PA) was used to determine the exchange between pollen samples and PASs. The results indicated that high-molecular-weight PCBs moved from air to pollen media (deposition) and low-molecular -weight PCB congeners passed from pollen media to air (volatilization) in both sampling areas.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available