Ask authors/readers for more resources

The study aimed to establish a classification system for extraglottic airway device misplacement and describe its frequency in decedents with the device in situ. Results showed that misplacement occurred in over 14% of cases, with a small percentage resulting in severe traumatic complications.
Study objective: Extraglottic airway devices are frequently used during cardiac arrest resuscitations and for failed intubation attempts. Recent literature suggests that many extraglottic airway devices are misplaced. The aim of this study is to create a classification system for extraglottic airway device misplacement and describe its frequency in a cohort of decedents who died with an extraglottic airway device in situ. Methods: We assembled a cohort of all decedents who died with an extraglottic airway device in situ and underwent postmortem computed tomographic (CT) imaging at the state medical examiner's office during a 6-year period, using retrospective data. An expert panel developed a novel extraglottic airway device misplacement classification system. We then applied the schema in reviewing postmortem CT for extraglottic airway device position and potential complications. Results: We identified 341 eligible decedents. The median age was 47.0 years (interquartile range 32 to 59 years). Out-of-hospital personnel placed extraglottic airway devices in 265 patients (77.7%) who subsequently died out of hospital; the remainder died inhospital. The classification system consisted of 6 components: depth, size, rotation, device kinking, mechanical blockage of ventilation opening, and injury. Under the system, extraglottic airway devices were found to be misplaced in 49 cases (14.4%), including 5 (1.5%) that resulted in severe injuries. Conclusion: We created a novel extraglottic airway device misplacement classification system. Misplacement occurred in greater than 14% of cases. Severe traumatic complications occurred rarely. Quality improvement activities should include review of extraglottic airway device placement when CT images are available and use the classification system to describe misplacements.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available