4.8 Article

Isothermal Amplification and Ambient Visualization in a Single Tube for the Detection of SARS-CoV-2 Using Loop-Mediated Amplification and CRISPR Technology

Journal

ANALYTICAL CHEMISTRY
Volume 92, Issue 24, Pages 16204-16212

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.0c04047

Keywords

-

Funding

  1. Canadian Institutes of Health Research
  2. New Frontiers in Research Fund
  3. Natural Sciences and Engineering Research Council of Canada
  4. Social Sciences and Humanities Research Council of Canada
  5. Alberta Innovates
  6. Alberta Health
  7. Li Ka Shing Institute of Virology

Ask authors/readers for more resources

We have developed a single-tube assay for SARS-CoV-2 in patient samples. This assay combined advantages of reverse transcription (RT) loop-mediated isothermal amplification (LAMP) with clustered regularly interspaced short palindromic repeats (CRISPRs) and the CRISPR-associated (Cas) enzyme Cas12a. Our assay is able to detect SARS-CoV-2 in a single tube within 40 min, requiring only a single temperature control (62 degrees C). The RT-LAMP reagents were added to the sample vial, while CRISPR Cas12a reagents were deposited onto the lid of the vial. After a half-hour RT-LAMP amplification, the tube was inverted and flicked to mix the detection reagents with the amplicon. The sequence-specific recognition of the amplicon by the CRISPR guide RNA and Cas12a enzyme improved specificity. Visible green fluorescence generated by the CRISPR Cas12a system was recorded using a smartphone camera. Analysis of 100 human respiratory swab samples for the N and/or E gene of SARS-CoV-2 produced 100% clinical specificity and no false positive. Analysis of 50 samples that were detected positive using reverse transcription quantitative polymerase chain reaction (RT-qPCR) resulted in an overall clinical sensitivity of 94%. Importantly, this included 20 samples that required 30-39 threshold cycles of RT-qPCR to achieve a positive detection. Integration of the exponential amplification ability of RT-LAMP and the sequence-specific processing by the CRISPR-Cas system into a molecular assay resulted in improvements in both analytical sensitivity and specificity. The single-tube assay is beneficial for future point-of-care applications.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available