4.5 Article

Low concentration of polyethylene glycol facilitates separation of extracellular vesicles from bronchoalveolar lavage fluid

Publisher

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/ajplung.00318.2020

Keywords

extracellular vesicle (EV); EV-cargo miRNAs; polyethylene glycol (PEG); ultracentrifugation (UC)

Funding

  1. National Institutes of Health (NIH) National Institute of Allergy and Infectious Diseases [R33 AI121644]
  2. NIH National Institute of General Medical Science [R01 GM127596]
  3. NIH [R01 GM111313]
  4. NIH National Heart, Lung, and Blood Institute [R01 HL142758-01A1]

Ask authors/readers for more resources

PEG concentration has a significant impact on the separation of EVs from BALF, with low concentration facilitating optimal EV separation. High concentrations of PEG altered various EV parameters and robustly reduced the levels of EV-cargo miRNAs compared to UC or low PEG methods.
Extracellular vesicles (EVs) in bodily fluids play an essential role in cell-cell cross talk and potentially serve as novel biomarkers in liquid biopsy. It is crucial to have a consistent, efficient, and reliable method to separate EVs from bodily fluids. Currently, there is no universally accepted, best method to separate EVs. Besides differential ultracentrifugation (UC), polyethylene glycol (PEG) is among the commonly used methods for EV separation from bodily fluids. However, the optimal concentration of PEG to be used remains inadequately addressed. We initially observed that the concentration of PEG has a significant impact on the amount of separated EVs and EV-cargos, which are recovered from bronchoalveolar lavage fluid (BALF). To determine the optimal PEG concentration to be used in EV separation from BALF, we first separated the BALF and serum from wild-type C57BL/6 mice. Next, various concentrations of PEG (5%, 10%, and 15% PEG), a commercial kit, and UC were used to obtain EVs from BALF and serum. EVs were characterized, and EV-cargo protein, RNA, and miRNA levels were determined. We found that high concentration of PEG (10% and 15%) altered various EV parameters that are frequently used in EV studies, including EV yield, purity, and morphology. Using miR-15a, miR-142, and miR-223 as examples, we found that 10% and 15% PEG robustly reduced the detected levels of EV-cargo miRNAs compared with those in the EVs separated using UC or 5% PEG. Collectively, low concentration of PEG facilitates the optimal BALF EV separation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available