There were statistically significant differences in WTW measurement among the four devices, with Anterion and IOLMaster 700 potentially being interchangeable, as well as Anterion and Pentacam HR. However, IOLMaster 700 and Pentacam HR, as well as Cassini with any of the other three devices, may not be interchangeable.
Purpose To assess the interchangeability of different devices for measuring white-to-white (WTW) distance. Methods WTW distance was measured in 53 eyes of 53 patients using Anterion swept-source optical coherence topographer (SS-OCT), IOLMaster 700 SS-OCT, Pentacam HR Scheimpflug and Cassini color LED. Statistical analysis was done by means of the Friedman test and the post hoc Tukey test. The Bland-Altman analysis was applied to carry out pairwise comparisons with the average difference, 95% confidence interval of the average difference and limits of agreement 95% (LoA). Results WTW values obtained by the Anterion, IOLMaster 700, Pentacam HR and Cassini were: 11.84 +/- 0.41 mm, 11.96 +/- 0.41 mm, 11.68 +/- 0.38 mm and 12.65 +/- 0.52 mm, respectively. Statistically significant differences were found in all pairwise comparison (p < 0.001). The lowest mean difference was found between the Anterion and IOLMaster 700 (- 0.11 mm) and the highest between the Pentacam HR and Cassini (- 0.96 mm). The widest LoA ranges were those that compared any device with the Cassini. LoA ranges when the other three devices were compared among them were similar: Anterion versus IOLMaster 700, Anterion versus Pentacam HR and IOLMaster versus Pentacam HR (about 0.2 mm). Conclusions Our results show that there were statistically significant differences in WTW measurement among the four devices, but under a clinical point of view, we believe that Anterion and IOLMaster 700 may be considered interchangeable and so Anterion and Pentacam HR, however, IOLMaster 700 and Pentacam HR may not and neither is Cassini with any of the other three devices.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available