4.5 Article

A Novel Parameter to Predict Supraclinoid Aneurysm Persistence After Flow Diversion with the Pipeline Embolization Device

Journal

WORLD NEUROSURGERY
Volume 145, Issue -, Pages E216-E223

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.wneu.2020.10.013

Keywords

Aneurysm; Flow diversion; Pipeline Embolization Device

Ask authors/readers for more resources

The study revealed that oversizing the stent and poor wall apposition can lead to aneurysm recurrence after PED placement due to elongation. A novel parameter based on two-dimensional imaging, the ML/NL ratio, was found to be significantly larger in nonoccluded aneurysms, suggesting it could predict aneurysm occlusion after PED placement.
BACKGROUND: Aneurysm recurrence after Pipeline Embolization Device (PED) placement can be caused by oversizing of the stent as well as poor wall apposition, both of which can lead to elongation. The objective of this study was to assess whether a novel parameter for measuring device elongation based on two-dimensional imaging could be predictive for persistent aneurysm filling after treatment with the PED. METHODS: A retrospective cohort analysis was initially completed on 41 aneurysms from institution A, examining demographic, aneurysmal, and device measurements. Device measurements, including the ratio of the measured length to the nominal length (ML/NL) of the PED, were taken by reviewers blinded to the primary end point, which was aneurysm occlusion status on 6 month catheter angiogram. Findings were then externally validated against 30 aneurysms (supraclinoid only) from institution B. RESULTS: Data from institution A showed 61% complete aneurysm occlusion at 6 months, and were lower for aneurysms in the supraclinoid region. For supraclinoid aneurysms alone, combined data from both institutions showed higher rates of nonocclusion with aneurysm neck size >4 mm (P = 0.008) and a trend toward significance in aneurysms with a branch vessel (P = 0.051). The mean ML/NL ratio was significantly larger in the nonoccluded group compared with the occluded group at both institution A (ratio, 1.37 versus 1.10; P < 0.001) and institution B (ratio, 1.36 vs. 1.11; P = 0.002). CONCLUSIONS: Our data suggest that a novel parameter based on two-dimensional angiography may serve as a rapid technique to measure device elongation and predict occlusion of supraclinoid aneurysms after PED placement.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available