4.7 Article

Stabilized zirconia-based acetone sensor utilizing Fe2TiO5-TiO2 sensing electrode for noninvasive diagnosis of diabetics

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 321, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2020.128489

Keywords

Gas sensor; Acetone; Stabilized zirconia; Fe2TiO5-TiO2; Diabetics

Funding

  1. National Natural Science Foundation of China [61831011, 61803171, 61520106003, 61722305, 61833006]
  2. Program for Chang Jiang Scholars and Innovative Research Team in University [IRT-17R47]
  3. National Key Research and Development Program of China [2016YFC0207300, 2016YFC0201002]
  4. Application and Basic Research of Jilin Province [20130102010 JC]
  5. Young Elite Scientists Sponsorship Program by CAST [2018QN RC001]
  6. Program for JLU Science and Technology Innovative Research Team [JLUSTIRT 2017TD-07]
  7. China Postdoctoral Science Foundation [2018M630322, 2019T120239]
  8. Jilin Provincial Science and Technology Development Program [20190103155JH]
  9. Jilin Provincial Education Department Science and Technology Project [JJKH20190114KJ]
  10. Fundamental Research Funds for the Central Universities

Ask authors/readers for more resources

Acetone detection in exhaled breath as a biomarker has been a new method for non-invasive diagnosis of diabetes in medical diagnosis. Here, we fabricated a stabilized zirconia (YSZ) solid electrolyte type acetone sensor based on mixed potential sensing mechanism using Fe2TiO5-TiO2 oxide sensing electrode (SE) prepared by a simple sol-gel method. The acetone sensing performance of the fabricated sensor attached with Fe2TiO5-TiO2-SE calcined at 1200 degrees C was evaluated at different working temperatures from 490 degrees C to 640 degrees C. The sensor exhibits the highest response values at all the evaluated concentrations of acetone at 590 degrees C, which even detects as low as 100 ppb acetone with the response value of -2.9 mV. The sensor displays high sensitivities of -13 mV/decade and -46 mV/decade in the acetone concentration ranges of 0.1 ppm - 1 ppm and 1 ppm - 20 ppm, respectively. Meanwhile, the selectivity, reproducibility, humidity/time stability of the developed sensing device are still impressive. Moreover, the breath analysis of healthy volunteers and diabetic volunteers was discussed to verify the application value of the sensor. The good acetone detectability of the developed sensor provides a potential for routine monitoring and early screening of diabetics.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available