4.6 Article

Bloch Surface Wave Resonance Based Sensors as an Alternative to Surface Plasmon Resonance Sensors

Journal

SENSORS
Volume 20, Issue 18, Pages -

Publisher

MDPI
DOI: 10.3390/s20185119

Keywords

Bloch surface wave resonance; surface plasmon resonance; Kretschmann configuration; multilayer plasmonic structure; multilayer dielectric structure; spectral interference; moist air; sensitivity; figure of merit

Funding

  1. Science and Research in the Moravia-Silesia Region 2019 [RRC/10/2019]
  2. Student Grant System [SP2020/45]

Ask authors/readers for more resources

We report on a highly sensitive measurement of the relative humidity (RH) of moist air using both the surface plasmon resonance (SPR) and Bloch surface wave resonance (BSWR). Both resonances are resolved in the Kretschmann configuration when the wavelength interrogation method is utilized. The SPR is revealed for a multilayer plasmonic structure of SF10/Cr/Au, while the BSWR is resolved for a multilayer dielectric structure (MDS) comprising four bilayers of TiO2/SiO2with a rough termination layer of TiO2. The SPR effect is manifested by a dip in the reflectance of ap-polarized wave, and a shift of the dip with the change in the RH, or equivalently with the change in the refractive index of moist air is revealed, giving a sensitivity in a range of 0.042-0.072 nm/%RH. The BSWR effect is manifested by a dip in the reflectance of the spectral interference ofs- andp-polarized waves, which represents an effective approach in resolving the resonance with maximum depth. For the MDS under study, the BSWRs were resolved within two band gaps, and for moist air we obtained sensitivities of 0.021-0.038 nm/%RH and 0.046-0.065 nm/%RH, respectively. We also revealed that the SPR based RH measurement is with the figure of merit (FOM) up to 4.7 x 10(-4)%RH-1, while BSWR based measurements have FOMs as high as 3.0 x 10-3%RH-1and 1.1 x 10(-3)%RH-1, respectively. The obtained spectral interferometry based results demonstrate that the BSWR based sensor employing the available MDS has a similar sensitivity as the SPR based sensor, but outperforms it in the FOM. BSW based sensors employing dielectrics thus represent an effective alternative with a number of advantages, including better mechanical and chemical stability than metal films used in SPR sensing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available