4.6 Article

Intra- and inter-observer variability in intracranial aneurysm segmentation: comparison between CT angiography (semi-automated segmentation software stroke VCAR) and digital subtraction angiography (3D rotational angiography)

Journal

RADIOLOGIA MEDICA
Volume 126, Issue 3, Pages 484-493

Publisher

SPRINGER-VERLAG ITALIA SRL
DOI: 10.1007/s11547-020-01275-y

Keywords

Innovative biotechnologies; Intracranial aneurysm; Stroke VCAR; CT angiography; Inter-observer variability

Ask authors/readers for more resources

The study compared the size and morphologic features of three-dimensional aneurysm models obtained using different methods, finding some differences in dimensions and characteristics. Differences were observed between manual and automatic measurements of aneurysm dimensions. Additionally, the presence of subarachnoid hemorrhage did not affect the three-dimensional reconstruction of aneurysms.
Purpose To compare size and morphologic features of three-dimensional aneurysm models, obtained with a semi-automated segmentation software (Stroke VCAR, GE, USA) from cerebral CT angiography (CTA) data, to three-dimensional aneurysm models obtained with digital subtraction angiography (DSA, with 3D rotational angiography acquisition-3DRA), considered as the reference standard. Methods In this retrospective study, we reviewed 132 patients, with a total number of 137 intracranial aneurysm, who underwent CTA and subsequent DSA examination, supplemented with 3DRA. We compared neck length, short axis and long axis measured on 3DRA model to the same variables measured on 3D-CTA model by two blinded readers and to the automatic software dimensions. Therefore, statistics analysis assessed intra-observer and inter-observer variability and differences between patients with or without subarachnoid hemorrhage (SAH). Results There were no significant differences in short-axis and long-axis measurements between 3D angiographic and 3D-CTA models, while comparison of neck lengths revealed a statistically significant difference, which tended to be greater for smaller neck lengths (partial volume effect and kissing vessels artifact). There were significant differences between manual and automatic data measured for the same three variables, and the presence of SAH did not affect aneurysm 3D reconstruction. Inter-observer agreement resulted moderate for neck length and substantial for short axis and long axis. Conclusion The examined 3D-CTA segmentation system is a reproducible procedure for aneurysm morphologic characterization and, in particular, for assessment of aneurysm sac dimensions, but considerable carefulness is required in neck length interpretation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available