Value of 10-2 Visual Field Testing in Glaucoma Patients with Early 24-2 Visual Field Loss

Journal

OPHTHALMOLOGY
Volume 128, Issue 4, Pages 545-553

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ophtha.2020.08.033

Keywords

Glaucoma; Perimetry; Receiver operating characteristic curve analysis; Sensitivity; Specificity; Visual field; 10-2 test; 24-2 test

Categories

Ask authors/readers for more resources

In the study comparing the 24-2 and 10-2 tests in glaucoma patients with early damage, it was found that the AUC values were not significantly different between the two tests, but the sensitivity of the 24-2 test was higher at matched specificity. The repeatability of test results during follow-up ranged from 55% to 70%.
Purpose: To determine whether the 10-2 test of the Humphrey Field Analyzer detected a higher proportion of abnormal visual fields compared with the 24-2 test in the central 10 degrees of patients with early glaucomatous visual field damage. Design: Prospective observational study. Participants: Patients with open-angle glaucoma and healthy control participants. Methods: All participants underwent a 24-2 and 10-2 test. Only the 12 central test locations of the 24-2 test were included to analyze equivalent visual field areas. The performance of the 2 tests was compared across 4 pointwise criteria: total deviation (TD) and pattern deviation (PD) analyses at the 5% and 2% levels. Analyses also were conducted for 2 pairs of follow-up tests, each performed 4 months apart. Main Outcome Measures: (1) Area under the receiver operating characteristic curve (AUC), (2) sensitivity at identically matched specificity for the 4 criteria, (3) overlap (entire field and by quadrant) of abnormal visual fields with both tests, and (4) repeatability of the findings in 2 subsequent follow-up tests. Results: One eye each of 97 glaucoma patients (median mean deviation, -2.31 dB) and 65 control participants were included in the study. The AUCs for the 24-2 and 10-2 tests were not significantly different for any of the 4 criteria and ranged from 0.88 to 0.93 and from 0.91 to 0.94, respectively. At matched specificity, the sensitivity of the 24-2 test was significantly higher for all criteria except for PD analysis at 5%. In patients with an abnormal field with either test, the overlap varied from 60% to 86% depending on the criterion, whereas by quadrant, concordance ranged from 70% to 87%. Over the follow-up, the repeatability of test results (both 24-2 and 10-2 abnormal, either abnormal, or both normal) was achieved in 55% to 70% of patients. Conclusions: In this study of glaucoma patients with early damage with the 24-2 test, there was little evidence that adding the 10-2 test revealed additional undetected defects in the central visual field. It may be more prudent to reserve 10-2 testing for following up selected patients with higher risk of central visual field progression. (C) 2020 by the American Academy of Ophthalmology

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available