4.7 Article

Magnetic solid phase extraction sorbents using methyl-parathion and quinalphos dual-template imprinted polymers coupled with GC-MS for class-selective extraction of twelve organophosphorus pesticides

Journal

MICROCHIMICA ACTA
Volume 187, Issue 9, Pages -

Publisher

SPRINGER WIEN
DOI: 10.1007/s00604-020-04465-7

Keywords

Dual-template; Magnetic molecularly imprinted polymers; Organophosphorus pesticides (OPPs)

Funding

  1. National Key Research and Development Programs of China [2017YFC1601600]
  2. National Ten thousand Plan Scientific and Technological Innovation Leading Talent Project
  3. Shandong Provincial Key Research and Development Program

Ask authors/readers for more resources

A novel magnetic dual-template molecularly imprinted polymer (DMIP) was prepared with methyl-parathion and quinalphos as templates. For comparison, a series of single-template polymers with only methyl-parathion (MPMIP) or quinalphos (QPMIP) as template as well as a non-imprinted polymer (NIP) in the absence of the template, were synthesized using the same procedure of DMIP. The obtained MIPs were characterized by scanning electron microscopy(SEM), Fourier transform infrared (FT-IR) spectroscopy, vibrating sample magnetometer (VSM), and X-ray diffraction (XRD). The properties including kinetic effect, thermodynamic effect, selectivity, and reusability of MIPs were investigated . Only DMIP possessed high affinity and good recognition for all twelve OPPs including quinalphos, isazophos, chlorpyrifos-methyl, chlorpyrifos, methidathion, triazophos, profenofos, fenthion, fenitrothion, methyl-parathion, parathion, and paraoxon in comparison to MPMIP, QPMIP, or NIP. Moreover, DMIP was used as magnetic solid phase extraction (MSPE) sorbent for the pre-concentration of twelve OPPs in cabbage samples. The developed DMIP-MSPE-GC-MS method showed high sensitivity, low LODs (1.62-13.9 ng/g), fast adsorption equilibrium (10 min), and acceptable spiked recoveries (81.5-113.4%) with relative standard deviations (RSD) in the range 0.05-7.0% (n = 3). The calibration plots were linear in the range 10-800 ng/mL with coefficients of determination (R-2) better 0.99 for all twelve compounds. These results suggest that the DMIP is applicable for rapid determination and high throughput analysis of multi-pesticide residues.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available