This study compared the use of shear wave elastography on the maternal cervix with transvaginal and transabdominal ultrasound approaches for assessing shear wave speeds. The results showed that TV approach obtained more SWS measurements at the anterior portion of the cervix, and produced significantly greater SWSs at the internal os compared to the TA approach.
Objectives This work aimed to compare the use of shear wave elastography on the maternal cervix with transvaginal (TV) and transabdominal (TA) ultrasound approaches to assess differences in shear wave speeds (SWSs) obtained for possible clinical use. Methods In both TV and TA ultrasound approaches, SWS measurements were attempted at the anterior and posterior portions of the internal and external cervicaloson 38 gravid participants. Results A larger number of SWS measurements were obtained at the anterior portion of the cervix by both approaches. The numbers of reliable measurements of the SWS obtained at the anterior and posterior portions of the internal and external os were 99, 65, 103, and 77 in the TA approach and 93, 53, 110, and 87 in the TV approach, respectively. The mean difference in -the SWS obtained between the TV and TA ultrasound approaches was statistically significant at the anterior and posterior portions of the internal os, with differences of 0.67 and 0.52 m/s (P < .05). Differences were not significant at the external os both anteriorly and posteriorly, with differences of 0.15 and - 0.07 m/s (P > .05). Conclusions Both TA and TV ultrasound approaches may be used to obtain SWSs in the maternal cervix. This study has shown that SWSs obtained by each approach need to be considered independently, as the TV approach produced significantly greater SWSs at the internal os compared to the TA approach, but the values were similar at the external os.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available