4.3 Article

Evaluation and applicability of Alere iCup DX 14 for rapid postmortem urine drug screening at autopsy

Journal

JOURNAL OF FORENSIC SCIENCES
Volume 66, Issue 1, Pages 375-382

Publisher

WILEY
DOI: 10.1111/1556-4029.14577

Keywords

autopsy; drug screen; forensic toxicology; immunoassay; point-of-care testing

Ask authors/readers for more resources

Performing point-of-care urine drug screen testing at autopsy by a forensic pathologist may offer early indication of presence of analytes; Evaluation of Alere iCup DX 14 for screening postmortem urine drug abuse; Sensitivity and specificity of iCup for various drug classes in comparison with confirmatory tests.
Performing point-of-care urine drug screen testing at autopsy by a forensic pathologist may provide an early indication of the presence of analytes of interest during autopsy. An evaluation for the screening of 14 classes of common drugs of abuse in postmortem urine by the point-of-care screening device, Alere iCup DX 14, is presented. One hundred ninety postmortem urine samples were screened with the iCup occurring at autopsy by the forensic pathologist. Positive and negative results obtained from the screening kit were evaluated against confirmatory test results obtained using routine forensic toxicology analyses that employed LC-MS/MS and GC-MS to detect a combination of over 85 common drugs of abuse and medications. Sensitivity for each respective iCup drug class ranged from 66% (buprenorphine) to 100% (methadone, tricyclic antidepressants). Specificity for each respective iCup drug class ranged from 89% (benzodiazepines) to 100% (amphetamines, barbiturates, buprenorphine, 3,4-methylenedioxymethamphetamine, methadone). Positive predictive values ranged from 44% (benzodiazepines) to 100% (amphetamines, barbiturates, buprenorphine, methylenedioxymethamphetamine, methadone), while negative predictive values ranged from 96% (methamphetamine) to 100% (barbiturates, methadone, tricyclic antidepressants). A high false-positive rate was yielded by the benzodiazepine class. The lack of fentanyl screening in the point-of-care device is a significant limitation considering its prolific prevalence in forensic casework. The results obtained in the study should be acknowledged when considering the use of the Alere iCup DX 14 in the context of postmortem casework to help indicate potential drug use contemporaneously with autopsy and when requiring such preliminary results prior to the release of a final forensic toxicology report.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available