4.6 Article

Left Ventricular Remodeling After Transcatheter Mitral Valve Replacement With Tendyne New Insights From Computed Tomography

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 13, Issue 17, Pages 2038-2048

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2020.06.009

Keywords

computed tomographic angiography; CTA; mitral regurgitation; MR; reserve remodeling; TMVR; transcatheter mitral valve replacement

Ask authors/readers for more resources

OBJECTIVES The aim of this study was to describe the anatomic and functional changes in left-sided chambers using computed tomographic angiography (CTA) from baseline to 1 month after transcatheter mitral valve replacement (TMVR) with the Tendyne prosthesis. BACKGROUND Data on changes in left atrial and left ventricular (LV) volumes after TMVR implantation are very limited. METHODS Patients who underwent TMVR with the Tendyne prosthesis between 2015 and 2018 were analyzed. Changes in LV end-diastolic volume, ejection fraction, LV mass, left atrial volume, and global longitudinal strain were assessed at baseline and 1 month after TMVR using CTA. Specific Tendyne implant characteristics were identified and correlated with remodeling changes. RESULTS A total of 36 patients (median age 74 years; interquartile range [IQR]: 69 to 78 years; 78% men; 86% with secondary mitral regurgitation) were included in this study. There were significant decreases in LV end-diastolic volume (281 ml [IQR: 210 to 317 ml] vs. 239 ml [IQR: 195 to 291 ml]; p < 0.001), LV ejection fraction (37% [IQR: 31% to 48%] vs. 30% [IQR: 23% to 40%]; p < 0.001), LV mass (126 g [IQR: 96 to 155 g] vs. 116 g [IQR: 92 to 140 g]; p < 0.001), left atrial volume (171 ml [IQR: 133 to 216 ml] vs. 159 ml [IQR: 125 to 201 ml]; p = 0.027), and global longitudinal strain (-11% [IQR: 17% to 8%] vs. -9% [IQR: 12% to -6%]; p < 0.001) from baseline to 1-month follow-up. Favorable LV end-diastolic volume reverse remodeling occurred in the majority (30 of 36 patients [83%]). Closer proximity of the Tendyne apical pad to the true apex (24 mm [IQR: 21 to 29 mm] vs. 35 mm [IQR: 26 to 40 mm]) was predictive of favorable remodeling (p = 0.037). CONCLUSIONS TMVR with Tendyne results in favorable left-sided chamber remodeling in the majority of patients treated, as detected on CTA at 1 month after implantation. CTA identifies favorable post-TMVR changes, which could be related to specific characteristics of the device implantation. (C) 2020 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available