Journal
FOOD ANALYTICAL METHODS
Volume 14, Issue 3, Pages 496-502Publisher
SPRINGER
DOI: 10.1007/s12161-020-01898-x
Keywords
MIP OES; DLLME; Sample preparation; Microextraction; Trace analysis
Categories
Funding
- Fundacao de Amparo a Pesquisa do Estado de Sao Paulo -Fapesp [2018/26145-9]
- Conselho Nacional de Desenvolvimento Cientifico e Tecnologico -CNPq [153125/2016-0, 141315/2017-2, 308178/2018-1]
- Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior Brazil [001]
Ask authors/readers for more resources
The sensitivity of molybdenum determination in lamb meat was improved using the DLLME-MIP OES method, with optimized operational parameters. The proposed method showed satisfactory accuracy and suitable sensitivity for analytical purposes.
The dispersive liquid-liquid microextraction (DLLME) was evaluated as a strategy to improve the MIP OES sensitivity for molybdenum determination in lamb meat. Initially, the dispersive (methanol) and extracting (tetrachloromethane) solvents were selected based on a mixture design. The best results were achieved with methanol and carbon tetrachloride as dispersive and extracting solvent, respectively. The operational parameters, such as pH, volume of dispersive and extractant solvents, and complexing agent concentration (8-hydroxyquinoline) were optimized using a Box-Behnken design. The optimal conditions were established as pH 3.8, 90 mu L of carbon tetrachloride, 480 mu L of methanol, and 1.09 mmol L(-1)of 8-hydroxyquinoline. Besides, the use of external gas module control (EGCM) was explored to minimize the matrix effects caused by the organic solvent introduction. The accuracy of the proposed method was estimated employing a certificate reference material (bovine liver, NIST 1577c) and the obtained recovery was 92%. The limit of detection was found to be 0.20 mu g g(-1), and the enrichment factor was 4.5. The DLLME-MIP OES was applied for six samples of lamb meat, and the results compared to ICP-MS presented no statistical difference. Therefore, the proposed method showed satisfactory accuracy and suitable sensitivity.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available