4.6 Article

Type A aortic dissection in aneurysms having modelled pre-dissection maximum diameter below 45 mm: should we implement current guidelines to improve the survival benefit of prophylactic surgery?

Journal

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
Volume 59, Issue 2, Pages 473-478

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1093/ejcts/ezaa351

Keywords

Aortic aneurysm; Aortic dissection; Acute aortic syndrome; Aortic surgery

Ask authors/readers for more resources

This study reviewed patients who underwent surgery for TAAD and found that 87.7% of patients experienced acute Type A aortic dissection (TAAD) at an aortic diameter below 45mm. The current aortic diameter threshold of 55mm excludes around 99% of TAAD patients from prophylactic ascending aorta replacement. The study suggests a need to reconsider the maximum diameter of the ascending aorta as part of a personalized decision-making process for preventive aorta replacement.
OBJECTIVES: Current guidelines recommend prophylactic replacement of the ascending aorta at an aneurysmal diameter of >55 mm to prevent acute Type A aortic dissection (TAAD) in non-Marfan patients. Several publications have challenged this threshold, suggesting that surgery should be performed in smaller aneurysms to prevent this devastating disease. We reviewed our experience with measuring aortic size at the time of TAAD to validate the existing recommendation for prophylactic ascending aorta replacement. METHODS: All patients who had been admitted for TAAD to our emergency department from 2014 to 2019 and underwent ascending aorta replacement were included. Marfan patients were excluded. The maximum diameter of the dissected aorta was measured preoperatively using CT scan. We estimated the aortic diameter at the time of dissection to be 7 mm smaller than the measured maximum diameter of the dissected aorta (modelled pre-dissection diameter). RESULTS: Overall, 102 patients were included. Of these, 67 were male (65.6%) and 35 were female (34.4%), and the cohort's mean age was 65 +/- 12.1 years. In addition, 66% were treated for arterial hypertension. The mean maximum modelled pre-dissection diameter was 39.6 +/- 4.8 mm: 39.1 +/- 5.1 mm in men and 40.7 +/- 2.8 mm in women (P= 0.1). The cumulative 30-day mortality rate was 19.6% (20/102). CONCLUSIONS: TAAD occurred at a modelled aortic diameter below 45 mm in 87.7% of our patients. Therefore, the current aortic diameter threshold of 55 mm excludes similar to 99% of patients with TAAD from prophylactic replacement of the ascending aorta. The maximum diameter of the ascending aorta warrants reappraisal and this parameter should be a distinct part of a personalized decision-making process that also takes into account age, gender and body surface area to establish the surgical indication for preventive aorta replacement aimed to improve the survival benefit of this procedure.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available