4.1 Article

Standardizing a volume benchmark for cerebrospinal fluids for optimal diagnostic accuracy

Journal

DIAGNOSTIC CYTOPATHOLOGY
Volume 49, Issue 2, Pages 258-266

Publisher

WILEY
DOI: 10.1002/dc.24635

Keywords

cerebrospinal fluid; CSF; flow cytometry; leptomeningeal disease; leukemia; lymphoma

Ask authors/readers for more resources

The study found that larger volumes of cerebrospinal fluid samples lead to more precise diagnostic results, recommending an optimal volume of 8.44 mL for cytologic evaluation of malignancies. However, optimal volumes may vary based on the type of malignancy and the use of flow cytometry.
Introduction: Cerebral spinal fluid (CSF) cytomorphologic analysis remains the gold standard in the evaluation of malignant leptomeningeal involvement. However, collection of optimal volumes for adequate cytomorphologic evaluation is not standardized. Our study investigated optimal CSF volumes that result in a significant diagnostic result. Methods: A total of 4114 samples were retrospectively identified from 2014 to 2018, and 2557 samples had concurrent flow cytometry (FC) study. Each specimen was grouped as unsatisfactory, negative, atypical, or positive. Positive samples were grouped as either solid tumors, leukemia, or lymphoma by the type of malignancy detected. Demographic data as well as CSF source was recorded. Specimens with FC were separated by detection on cytology and/or FC. At-test and ANOVA test were used to compare the average volumes for each group. Results: Average volumes for negative, atypical, and positive samples are 7.48 mL (95% CI: 7.33, 7.63), 7.97 mL (95% CI: 7.37, 8.57), and 8.44 mL (95% CI: 7.46, 9.43), respectively. Average volumes for solid tumors, leukemia, and lymphoma positive samples are 12.0 mL (95% CI: 9.11, 14.89), 6.73 mL (95% CI: 5.94, 7.53), and 8.44 mL (95% CI: 6.78, 10.09). For cases with FC, the volumes are 10.11 mL (95% CI: 9.28, 10.96), 7.28 mL (95% CI: 6.87, 7.70), and 6.86 mL (95% CI: 6.25, 7.49) for positive cytology only, positive cytology/FC, and negative for both, respectively. Conclusions: Our results suggest that higher volumes produce better results for analysis. We recommend an optimal volume of 8.44 mL for cytologic work-up of malignancies. However, optimal volumes may differ based upon malignancy type and utilization of flow cytometry.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available