A Model Averaging/Selection Approach Improves the Predictive Performance of Model-Informed Precision Dosing: Vancomycin as a Case Study

Journal

CLINICAL PHARMACOLOGY & THERAPEUTICS
Volume 109, Issue 1, Pages 175-183

Publisher

WILEY
DOI: 10.1002/cpt.2065

Keywords

-

Funding

  1. St Vincent's Curran Foundation Endowment Fund, Australia

Ask authors/readers for more resources

The study introduces automated model selection algorithm and model averaging algorithm for more accurate predictions in individualized drug dosing. The algorithms outperform single models in simulation studies and clinical datasets, providing more precise and accurate predictions. The implementation of MSA and MAA in MIPD software could potentially simplify individual model validation and streamline precision dosing.
Many important drugs exhibit substantial variability in pharmacokinetics and pharmacodynamics leading to a loss of the desired clinical outcomes or significant adverse effects. Forecasting drug exposures using pharmacometric models can improve individual target attainment when compared with conventional therapeutic drug monitoring (TDM). However, selecting the correct model for this model-informed precision dosing (MIPD) is challenging. We derived and evaluated a model selection algorithm (MSA) and a model averaging algorithm (MAA), which automates model selection and finds the best model or combination of models for each patient using vancomycin as a case study, and implemented both algorithms in the MIPD software TDMx. The predictive performance (based on accuracy and precision) of the two algorithms was assessed in (i) a simulation study of six distinct populations and (ii) a clinical dataset of 180 patients undergoing TDM during vancomycin treatment and compared with the performance obtained using a single model. Throughout the six virtual populations the MSA and MAA (imprecision: 9.9-24.2%, inaccuracy: less than +/- 8.2%) displayed more accurate predictions than the single models (imprecision: 8.9-51.1%; inaccuracy: up to 28.9%). In the clinical dataset, the predictive performance of the single models applying at least one plasma concentration varied substantially (imprecision: 28-62%, inaccuracy: -16 to 25%), whereas the MSA or MAA utilizing these models simultaneously resulted in unbiased and precise predictions (imprecision: 29% and 30%, inaccuracy: -5% and 0%, respectively). MSA and MAA approaches implemented in TDMx might thereby lower the burden of fit-for-purpose validation of individual models and streamline MIPD.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available