4.5 Article

Comparison of the effects of air-powder abrasion, chemical decontamination, or their combination in open-flap surface decontamination of implants failed for peri-implantitis: an ex vivo study

Journal

CLINICAL ORAL INVESTIGATIONS
Volume 25, Issue 5, Pages 2667-2676

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00784-020-03578-w

Keywords

Air-powder abrasion; Chemical decontamination; Peri-implantitis

Funding

  1. Universita degli Studi di Roma La Sapienza within the CRUI-CARE Agreement

Ask authors/readers for more resources

In an ex vivo model, mechanical debridement was found to be significantly more effective than chemical decontamination in removing bacterial biofilms from infected implant surfaces.
Objectives To compare, using an ex vivo model, the biofilm removal of three surface decontamination methods following surgical exposure of implants failed for severe peri-implantitis. Materials and methods The study design was a single-blind, randomized, controlled, ex vivo investigation with intra-subject control. Study participants were 20 consecutive patients with at least 4 hopeless implants, in function for >12 months and with progressive bone loss exceeding 50%, which had to be explanted. Implants of each patient were randomly assigned to the untreated control group or one of the three decontamination procedures: mechanical debridement with air-powder abrasion, chemical decontamination with hydrogen peroxide and chlorhexidine gluconate, or combined mechanical-chemical decontamination. Following surgical exposure, implants selected as control were retrieved, and afterwards, test implants were decontaminated according to allocation and carefully explanted with a removal kit. Microbiological analysis was expressed in colony-forming-units (CFU/ml). Results A statistically significant difference (p< 0.001) in the concentrations of CFU/ml was found between implants treated with mechanical debridement (531.58 +/- 372.07) or combined mechanical-chemical decontamination (954.05 +/- 2219.31) and implants untreated (37,800.00 +/- 46,837.05) or treated with chemical decontamination alone (29,650.00 +/- 42,596.20). No statistically significant difference (p = 1.000) was found between mechanical debridement used alone or supplemented with chemical decontamination. Microbiological analyses identified 21 microbial species, without significant differences between control and treatment groups. Conclusions Bacterial biofilm removal from infected implant surfaces was significantly superior for mechanical debridement than chemical decontamination.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available