4.7 Article

Criterion validity of ultrasound in the identification of calcium pyrophosphate crystal deposits at the knee: an OMERACT ultrasound study

Journal

ANNALS OF THE RHEUMATIC DISEASES
Volume 80, Issue 2, Pages 261-267

Publisher

BMJ PUBLISHING GROUP
DOI: 10.1136/annrheumdis-2020-217998

Keywords

-

Categories

Ask authors/readers for more resources

This study demonstrated the accuracy of ultrasound in diagnosing CPPD, with the highest sensitivity and specificity achieved by assessing the medial meniscus and medial condyle hyaline cartilage in combination. There were no differences in terms of inflammation between patients with CPPD and OA and those with OA alone.
Objective To evaluate the discriminatory ability of ultrasound in calcium pyrophosphate deposition disease ( CPPD), using microscopic analysis of menisci and knee hyaline cartilage (HC) as reference standard. Methods Consecutive patients scheduled for knee replacement surgery, due to osteoarthritis (OA), were enrolled. Each patient underwent ultrasound examination of the menisci and HC of the knee, scoring each site for presence/absence of CPPD. Ultrasound signs of inflammation (effusion, synovial proliferation and power Doppler) were assessed semiquantitatively (0-3). The menisci and condyles, retrieved during surgery, were examined microscopically by optical light microscopy and by compensated polarised microscopy. CPPs were scored as present/absent in six different samples from the surface and from the internal part of menisci and cartilage. Ultrasound and microscopic analysis were performed by different operators, blinded to each other's findings. Results 11 researchers from seven countries participated in the study. Of 101 enrolled patients, 68 were included in the analysis. In 38 patients, the surgical specimens were insufficient. The overall diagnostic accuracy of ultrasound for CPPD was of 75%-sensitivity of 91% (range 71%-87% in single sites) and specificity of 59% (range 68%-92%). The best sensitivity and specificity were obtained by assessing in combination by ultrasound the medial meniscus and the medial condyle HC (88% and 76%, respectively). No differences were found between patients with and without CPPD regarding ultrasound signs of inflammation. Conclusion Ultrasound demonstrated to be an accurate tool for discriminating CPPD. No differences were found between patents with OA alone and CPPD plus OA regarding inflammation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available