4.7 Article

Target-triggered signal-off electrochemical aptasensor assisted by Au nanoparticle-modified sensing platform for high-sensitivity determination of circulating tumor cells

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 412, Issue 29, Pages 8107-8115

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-020-02940-x

Keywords

Circulating tumor cells; Aptamer; Electrochemical biosensor; Au nanoparticles

Funding

  1. National Natural Science Foundation of China [81430053, 81401751, 81972027]
  2. Chongqing Health Commission [2018QNXM049, 2019ZDXM025]
  3. Medical pre-research project of the Army Medical University [2018XYY04]

Ask authors/readers for more resources

In this study, we fabricated a high-sensitivity signal-off electrochemical aptasensing platform for quantifying circulating tumor cells (CTCs) based on target-triggered signal readout of methylene blue (MB). Au nanoparticles (AuNPs) were introduced to enlarge the specific surface area of the gold electrode (GE), which would immobilize homogeneous and more MB-aptamers. MB-modified and stem-loop-like aptamers were assigned as a recognition element with K562 cells. Thiolated complementary strands hybridized with MB-aptamers to form double-stranded DNA (dsDNA) conformation which were further self-assembled on the surface of AuNP-modified GE, leading to a marked current peak of MB signal. In the presence of K562 cells, the MB-aptamers preferred to recognize and bind with the cells, causing the disassembly of MB-aptamers from the GE surface. Therefore, the reduced value of MB signal was related to the number of K562 cells. With the proposed aptasensor, a dynamic linear range from 1 x 10(2)to 1 x 10(6) cells mL(-1) was obtained with a detection limit of 23 cells mL(-1). Moreover, the aptasensor showed good selectivity, stability, and reproducibility as well as potential use in the clinical setting. Meanwhile, characterization techniques such as field-emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, atomic force microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy were performed to analyze the evolution of the morphology and each fabricated step of the constructed aptasensor. Our proposed aptasensor could be designed as a universal platform for CTC determination by replacing tumor cell-specific aptamers, which is a promising strategy for basic research and clinical applications.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available