4.6 Article

Bruch's Membrane Opening Minimum Rim Width Provides Objective Differentiation between Glaucoma and Nonglaucomatous Optic Neuropathies

Journal

AMERICAN JOURNAL OF OPHTHALMOLOGY
Volume 218, Issue -, Pages 164-172

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ajo.2020.05.034

Keywords

-

Categories

Funding

  1. Sydney Hospital Foundation, Sydney Eye Hospital, Macquarie St, Sydney Australia

Ask authors/readers for more resources

PURPOSE: A challenging clinical scenario is distinguishing between normal tension glaucoma (NTG) and non-glaucomatous optic neuropathies (NGON). The key to the assessment remains identifying the presence of optic nerve head cupping. Recent optical coherence tomography (OCT) measurements now allow objective assessment of cupping by minimum rim width at Bruch's membrane opening (MRW-BMO). This study assessed the hypothesis that the MRW-BMO measurement quantifies cupping and therefore can differentiate between NTG and NGON. DESIGN: Diagnostic evaluation with area under the curve. METHODS: Setting: multicenter tertiary hospitals and outpatient clinics. Patient population: 81 eyes of 81 patients were enrolled, 27 with NTG and 54 with NGON, including ischemic optic neuropathy, previous optic neuritis, and compressive and inherited optic neuropathies. All NGON patients with intraocular pressure >21 mm Hg, narrow drainage angles, or a family history of glaucoma were excluded. Observational procedure: optic disc OCT images were obtained of both the retinal nerve fiber layer thickness and the MRW-BMO. Main outcome measurements: the utility of the MRW-BMO in differentiating GON from NGON was assessed using the area under the curve (AUC) estimated from a logistic regression model. RESULTS: The 5-fold cross-validated AUC for glaucoma versus nonglaucoma from logistic regression models using MRW-BMO values from all sectors was 0.95 (95% confidence interval: 0.86-1.00) CONCLUSIONS: The measurement of MRW-BMO effectively differentiates between NTG and NGON with a high level of sensitivity and specificity. Incorporating this measurement into routine glaucoma assessment may provide a robust method of assisting clinicians to improve diagnosis and therefore treatment of optic nerve diseases. ((C) 2020 Elsevier Inc. All rights reserved.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available