4.6 Article

Biomechanics of Aortic Dissection: A Comparison of Aortas Associated With Bicuspid and Tricuspid Aortic Valves

Journal

Publisher

WILEY
DOI: 10.1161/JAHA.120.016715

Keywords

aortic aneurysm; aortic dissection; bicuspid aortic valve; biomechanics

Funding

  1. University of Toronto's Medicine by Design initiative
  2. Canada First Research Excellence Fund (CFREF)
  3. University of Toronto EMHSeed Program

Ask authors/readers for more resources

Background Current methods for aortic dissection risk assessment are inadequate for patients with ascending aortic aneurysms associated with either bicuspid aortic valves (BAVs) or tricuspid aortic valves (TAVs). Biomechanical testing of aortic tissue may provide novel insights and biomarkers. Methods and Results From March 2017 to August 2019, aneurysmal ascending aortas (BAV=23, TAV=23) were collected from elective aortic surgery, normal aortas from transplant donors (n=9), and dissected aortas from surgery for aortic dissection (n=7). These aortas underwent delamination testing in simulation of aortic dissection. Biaxial tensile testing was performed to determine modulus of elasticity (aortic stiffness), and energy loss (a measure of efficiency in performing the Windkessel function). Delamination strength (S-d) was lowest in dissected aortas (186 mN/mm) and highest in normal aortas (58 +/- 16 mN/mm), and aneurysms fell in between, with greater S-d in the BAV group (37 +/- 10 mN/mm) than the TAV group (27 +/- 10 mN/mm) (P<0.001). Bicuspid aortopathy was associated with greater stiffness (P<0.001), while aneurysms with TAV demonstrated greater energy loss (P<0.001). S-d decreased by 7.81.2 mmol/L per mm per decade of life (r(2)=0.45, P<0.001), and it was significantly lower for patients with hypertension (P=0.001). S-d decreased by 6.12.1 mmol/L per mm with each centimeter increase in aortic diameter (r(2)=0.15, P=0.007). Increased energy loss was associated with decreased S-d (r(2)=0.41), whereas there was no relationship between S-d and aortic stiffness. Conclusions Aneurysms with BAV had higher S-d than those with TAV, suggesting that BAV was protective. Energy loss was lower in aneurysms with BAV, and inversely associated with S-d, representing a potential novel biomarker.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available