4.5 Article

Reliability of ITV approach to varying treatment fraction time: a retrospective analysis based on 2D cine MR images

Journal

RADIATION ONCOLOGY
Volume 15, Issue 1, Pages -

Publisher

BMC
DOI: 10.1186/s13014-020-01530-6

Keywords

Intra-fraction motion management; Internal target volume; MR-guided radiotherapy

Ask authors/readers for more resources

Background Internal Target Volume (ITV) is one of the most common strategies to passively manage tumour motion in Radiotherapy (RT). The reliability of this approach is based on the assumption that the tumour motion estimated during pre-treatment 4D Computed Tomography (CT) acquisition is representative of the motion during the whole RT treatment. With the introduction of Magnetic Resonance-guided RT (MRgRT), it has become possible to monitor tumour motion during the treatment and verify this assumption. Aim of this study was to investigate the reliability of the ITV approach with respect to the treatment fraction time (TFT) in abdominal and thoracic lesions. Methods A total of 12 thoracic and 15 abdominal lesions was analysed. Before treatment, a 10-phase 4DCT was acquired and ITV margins were estimated considering the envelope of the lesion contoured on the different 4DCT phases. All patients underwent MRgRT treatment in free-breathing, monitoring the tumour position on a sagittal plane with 4 frames per second (sec). ITV margins were projected on the tumour trajectory and the percentage of treatment time in which the tumour was inside the ITV (%TT) was measured to varying of TFT. The ITV approach was consideredmoderately reliablewhen %TT >= 90% andstrongly reliablewhen %TT >= 95%. Additional ITV margins required to achieve %TT >= 95% were also calculated. Results In the analysed cohort of patients, ITV strategy can be consideredstrongly reliableonly for lung lesions with TFT <= 7 min (min). The ITV strategy can be considered onlymoderately reliablefor abdominal lesions, and additional margins are required to obtain %TT >= 95%. Considering a TFT <= 4 min, additional margins of 2 mm in cranio-caudal (CC) and 1 mm in antero-posterior (AP) are suggested for pancreatic lesions, 3 mm in CC and 2 mm in AP for renal and liver ones. Conclusions On the basis of the analysed cases, the ITV approach appears to be reliable in the thorax, while it results more challenging in the abdomen, due to the higher uncertainty in ITV definition and to the observed larger intra and inter-fraction motion variability. The addition of extra margins based on the TFT may represent a valid tool to compensate such limitations.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available