4.5 Article

Droplet and Aerosol Generation With Endonasal Surgery: Methods to Mitigate Risk During the COVID-19 Pandemic

Journal

OTOLARYNGOLOGY-HEAD AND NECK SURGERY
Volume 164, Issue 2, Pages 285-293

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/0194599820949802

Keywords

endonasal; skull base; aerosol; droplet; COVID-19; prevention; safety

Ask authors/readers for more resources

This study utilized fluorescent 3D printed models and cadaveric specimens for simulation experiments, finding that the use of suction during endonasal surgery can significantly reduce aerosol risk.
Objective. To define the aerosol and droplet risks associated with endonasal drilling and to identify mitigation strategies. Study Design. Simulation series with fluorescent 3-dimensional (3D) printed sinonasal models and deidentified cadaveric heads. Settings. Dedicated surgical laboratory. Subjects and Methods. Cadaveric specimens irrigated with fluorescent tracer and fluorescent 3D-printed models were drilled. A cascade impactor was used to collect aerosols and small droplets of various aerodynamic diameters under 15 mu m. Large droplet generation was measured by evaluating the field for fluorescent debris. Aerosol plumes through the nares were generated via nebulizer, and mitigation measures, including suction and SPIWay devices, nasal sheaths, were evaluated regarding reduction of aerosol escape from the nose. Results. The drilling of cadaveric specimens without flexible suction generated aerosols <= 3.30 mu m, and drilling of 3D sinonasal models consistently produced aerosols <= 14.1 mu m. Mitigation with SPIWay or diameter-restricted SPIWay produced same results. There was minimal field contamination in the cadaveric models, 0% to 2.77% field tarp area, regardless of drill burr type or drilling location; cutting burr drilling without suction in the 3D model yielded the worst contamination field (36.1%), followed by coarse diamond drilling without suction (19.4%). The simple placement of a flexible suction instrument in the nasal cavity or nasopharynx led to complete elimination of all aerosols <= 14.1 mu m, as evaluated by a cascade impactor positioned immediately at the nares. Conclusion Given the findings regarding aerosol risk reduction, we strongly recommend that physicians use a suction instrument in the nasal cavity or nasopharynx during endonasal surgery in the COVID-19 era.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available